User Guide

PAMS
Technical Documentation
NSB–1/3
Service Software Instructions
Page 28
Original 06/98
When calibration is ended, the DAC value checking is made and if it is not
succeeded, error message is shown.
When exit is made, the next selections are set to the values which were
selected before this adjustment.
Operation Mode
Update RF Information window
The exit and the use of AGC–control values is done same way as exit
from power level tuning and power coefficient use:
Tx
Power... command
Activation Status Bar Text
Alt, T,P Open TX Power Tuning dialog box
Starts TX power tuning.
User is first requested to select with which values tuning is started in Start
Tuning dialog.
Start Tuning dialog has following items:
Start Tuning With list box (ALT+S):
Current Values in PC memory
Tuning values are load from program’s internal memory.
EEPROM Values
Tuning values are load from ME’s EEPROM.
Factory Default Values
Tuning values are load from ME’s flash.
The next automatic selections are made when this tuning function is acti-
vated:
the lowest (19) power level is selected
Operation mode = TX pulsed