PAMS Technical Documentation NSB–1/3 Series Transceivers Service Software Instructions Original 06/98
PAMS NSB–1/3 Service Software Instructions Technical Documentation CONTENTS Service Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 3.1x . . . . . . . . . . . Hardware requirements for Windows 95 . . . . . . . . . . . . Software Environment of the Support Modules . . . . . . . . . Required Servicing Equipment . . . . . . . . . . . . .
PAMS NSB–1/3 Technical Documentation Service Software Instructions NSB–1/3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Menu bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . New command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Open... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Initialise..
PAMS NSB–1/3 Service Software Instructions Technical Documentation View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Quick/RF Info... command . . . . . . . . . . . . . . . . . . . . . . . . Phone Information... command . . . . . . . . . . . . . . . . . . . . 63 63 64 Appendix 1, Vocabulary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PAMS NSB–1/3 Technical Documentation Service Software Instructions Service Software General To run the After Sales SW, a parallel port software protection device (PKD–1) has to be connected. TDF–4 box must connected to PC for flashing purposes. The user can use WinTesla functions in modules for testing NSB/E/K/M–1/3 mobile stations (MS). The test functions send test messages from PC to MS and receive results and show them in the PC display. The messages can be sent via M2BUS or FBUS.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Required Servicing Equipment – Computer: IBM 486 or compatible with one unused serial port (COM1 or COM2) *), one parallel port (LPT1), 5 Mb hard disk required. – Operating System: DOS Version 5.0 or later running MS Windows 3.1 or 3.11 or 95 or NT. – Display: Any supported by MS Windows 3.1 or 3.11 or Windows 95 – WinTesla Service software version for 3.5” disk (code: 0774046) – Service software version for 3.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Installation Mechanical Connections Caution: Make sure that you have switched off the PC and the printer before making connections. Caution: Do not connect the PKD–1 key to the serial port. You may damage your PKD–1 ! The software controls the phone via a separate adapter connected to the serial port of the PC, and to the telephone’s M2BUS (DAU–9P). Attach the dongle PKD–1 to the parallel port 1 (25–pin female D–connector) of the PC.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Installing the Software on PC Hard Disk The program is delivered on a diskette and is copy protected with a dongle PKD–1. It must be present in parallel port when using Service software. The program can also be installed on the hard disk, which is recommendable to obtain a maximum data access rate.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Common Properties of the User Interface This chapter describes how the User Interface CLF must appear to the user. The User Interface MUST be capable of being driven without the use of a mouse, as the service engineer rarely has space on the bench to use a mouse. Login Dialog When the Service Software application is invoked, by checking on the Service Software icon, the Login dialog box will be displayed on the screen.
PAMS NSB–1/3 Service Software Instructions Technical Documentation OK button (default key) The user name is stored in memory and the dialog box is closed. When the dialog box is closed, the application starts. Cancel button (ESC) The Dialog box is closed and application is started, but the Faultlog feature is disabled. Help button (F1) Activates the Windows Help application and displays context sensitive Help.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Title bar The title bar is located at the top of the window. A title bar contains the following elements: • Application Control–menu button • Maximise button • Minimise button • Name of the application • Restore button The properties of these elements and their usage is described in Ref 3– Microsoft Windows Version 3.1 Users Guide chapter one (Windows Basics) and chapter two (Application Basics).
PAMS NSB–1/3 Service Software Instructions Technical Documentation Menu bar The menu bar is below the title bar and contains all available menu selections. The menu bar is a dynamic element and is dependent on the dongle type fitted, and whether a phone is connected. Underlined characters in menu names and options indicates that the menu selection can be done by pressing Alt+ underlined character.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Menu Bar The Service Software package will have two menu bar configurations. The first, is an abbreviated version that contains the minimum number of menus that allows package configurations when a phone is NOT connected.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Configure The Configure menu contains the following items: • Options... • Directories... • Faultlog... • Phone Type Specific configuration items (where applicable) Tuning The Tuning menu contains the following menu sections: • RX Calibration... • Tx Power... • Tx I/Q... • Energy Management Calibration... Testing The Testing menu contains the following sections: • RF Controls... • RSSI Reading ...
PAMS NSB–1/3 Technical Documentation Service Software Instructions Software The Software menu contains the following menu sections: • Product Profile... • Start Up Self–tests... • Set Factory Values • Phone Identity... • Warranty State... • Production Data Edit... • Flash Phone... Dealer The Dealer menu contains the following menu sections: • User Settings... • Short Code Memory... • SCM & User settings ... • Restore User defaults ... • Set UI/DEV Default Values ... • Post–programming memory...
PAMS NSB–1/3 Service Software Instructions Technical Documentation Phone Information Window The Phone Identity window should contain, as a minimum, the following data: • Software Version(s) • Hardware Version(s) • Serial Number(s) • Product Code This window will only be used as a display window and therefore will not allow editing of the displayed data. This window will not contain any controls other than a scroll bar.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Mouse Cursors The standards Windows pointer will be used as the mouse cursor. During time consuming tasks e.g. communication to phone, an hour glass will be shown informing the user that a task is in progress. The application uses the hour glass cursor to inform user that the application has taken the control and any actions from user will be ignored.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Product – New NMP Key by Description Defined Shift+F5 Local Mode NMP Key by Description Defined Alt+P Product Menu NMP Alt+P,N New NMP Alt+P,O Open NMP Alt+P,C Close NMP Alt+P,I Initialize Pop–up NMP Alt+P,I,N Normal Mode NMP Alt+P,I,L Local Mode NMP Alt+P,F Faultlog Pop–up NMP Alt+P,F,A Activate Faultlog NMP Alt+P,F,E Edit Faultlog NMP Alt+P,X Exit Application NMP Alt+C Configure NMP Alt+C,O
PAMS NSB–1/3 Service Software Instructions Technical Documentation Alt+E,S Self Tests NMP Alt+E,A ADC Readings NMP Alt+E,U Audio NMP Alt+E,U,I Audio Internal NMP Alt+E,U User Interface NMP Alt+E,C Call Simulation NMP Alt+E,N Noise Sensitivity NMP Alt+E,I IR Test NMP Alt+S Software Menu NMP Alt+S,I Phone Identity NMP Alt+S,P Product Profile NMP Alt+S,S Start–up Self Tests NMP Alt+S,V Set Default Values NMP Alt+S,I Phone Identity NMP Alt+S,D Production Data Edit
PAMS NSB–1/3 Service Software Instructions Technical Documentation Help Functions The Help User Interface will be the standard Windows help tool called WinHelp. The context sensitive help is activated with F1–key. Help contains also Using Help which describes how to use help facility. Refer to the Windows manual for detailed description on the Windows Help. Dialog boxes The Service Software application uses many different dialog boxes. Dialog boxes are used to display data and prompt the user for input.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Query Message Box Confirmations and questions are asked in a query message box. A query dialog box is recognized by the ?–icon. The dialog box will also contain a Yes button, a No button, and a Help button. Yes button (Alt+Y or Y) (default key): Accepts confirmation or question. No button (Alt+N or N): Denies confirmation or question. Help button (Alt+H): Opens context sensitive help as F1–key does.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Custom Dialog boxes All custom dialog boxes will contain the predefined buttons as defined below in the section – Buttons. However, it is recognised that features may require additional button types, but the addition of these non–standard buttons should be carefully considered to minimise any inconsistencies between implementations. The buttons will be positioned down the right–hand side of the dialog boxes.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Yes button (ALT+Y or Y): Replies Yes to a question asked of the user. No button (ALT+N or N): Replies No to a question asked of the user. Help button (ALT+H): Opens context sensitive help as F1–key does. Reporting Status The status bar will be used to report the present status to the user. When a feature is initiated, the status bar will be updated with a brief description of the function.
PAMS NSB–1/3 Service Software Instructions Technical Documentation NSB–1/3 FEATURES Menu bar After Sales SW’s menus follows the menu structure specified in WinTesla User Interface Specification. This specification will describe functionality that differs from WinTesla specification. Product New command Activation Status Bar Text Alt, P, N Rescan a new phone Ctrl+R If phone is changed (with same phone type only serial number is changed) phone will be initialised to local mode.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Normal Mode Activation Status Bar Text Alt, P, I, N Initialises phone to normal mode F5 When normal mode has been activated or program has been started, self–test results will be asked from MCU. If any fault was found in the tests, an error message is shown. If normal mode has been set successfully (no self test error has been found), and paging listening has been started, the used AFC value is requested from MS.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Tuning The tuning menu offers functions for ME adjustments. RX Calibration... command Activation Status Bar Text Alt, T,R Open RX Calibration dialog box Starts RX calibration. The next automatic selections are made when this tuning function is activated: • Phone is set to local mode (Note! Shift F5 sets local mode) • Update RF information window The measurement is started automatically when RX calibration is entered.
PAMS NSB–1/3 Technical Documentation Service Software Instructions 4. Measurement with low input level is executed 5. The RX Calibration dialog will be updated when previous steps are done. Dialog mode: modal RX Calibration dialog has the following items: AFC information box: Shows AFC init value, AFC slope and PSW slope values. AGC List box (ALT+A): AGC, DAC, Voltage and Difference.
PAMS NSB–1/3 Service Software Instructions Technical Documentation When calibration is ended, the DAC value checking is made and if it is not succeeded, error message is shown. When exit is made, the next selections are set to the values which were selected before this adjustment. Operation Mode Update RF Information window The exit and the use of AGC–control values is done same way as exit from power level tuning and power coefficient use: Tx Power...
PAMS NSB–1/3 Technical Documentation Service Software Instructions The TX Power Tuning dialog will be activated automatically after value selection. Dialog mode: modal TX Power Tuning dialog has following items: Power Level & Coefficients list box (ALT+L): The power is presented in GSM or PCN values. The base power is selected automatically when the dialog is opened. The test value is not saved to the EEPROM.
PAMS NSB–1/3 Service Software Instructions Technical Documentation + and – buttons will cause power changing by 0.25dB steps. When these keys are used the coefficient value is updated on the tuning window. Save button (ENTER): Dialog is closed and tuned values are saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone. When selections are used, the power value checking is made and if it is not succeeded, error message is shown.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Tune TX I DC Offset scroll bar (ALT+I): The DC Offset is shown as percents (%) from the ± maximum value. 0% means that there is no DC. The value range is –100%...100%. The value is rounded to the nearest integer value. Tune TX Q DC Offset scroll bar (ALT+Q): The operation of this function is the same as one above, except with this selection the Q branch DC Offset is tuned. The value range is –100%...100%.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Energy Management Calibration... command Activation Status Bar Text Alt, T,E Energy Management Calibration This command opens the Energy Management Calibration dialog box: The Energy Management Calibration dialog box contains the following options: Run button (ALT+R) or ENTER: Energy management calibration is performed, Close button : The dialog box is closed without performing energy management calibration.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Testing The Testing sub menu offers functions for ME testing. RF Controls... command Activation Status Bar Text Alt, E,R Open RF Controls dialog box This function is used for RF testing. Command opens RF Controls dialog, which contains data for testing and adjustments.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Note! Function is activated immediately, Apply is not needed. TX radio button (ALT+T): When TX is selected, the next functions are made: Data transmission is activated If operation mode is continuous, – Operation mode is set to burst RF Information window is updated Continuous mode radio button is disabled. Note! Function is activated immediately, Apply is not needed.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Channel edit box (ALT+N): User can enter here channel number that is used for both transmission and receiving. The frequency of the selected channel is shown after selection. Monitoring Channel edit box (ALT+M): This field selects neighbour monitoring channel. The frequency of the selected channel is shown after selection.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Active Unit = RX Update RF Information window The next table shows the dialog’s properties on different situations: ACTIVE UNIT = TX: TX Data Type: Updated AGC values: Greyed Monitoring Channel: Greyed OPERATION MODE = BURST: TX Power Level: Updated Continuous Mode Channel: Greyed Channel: Updated ACTIVE UNIT = RX: TX Data Type: Greyed TX Power Level: OFF, Greyed OPERATION MODE = BURST: AGC values: Greyed Continuous Mode Channel: Greyed C
PAMS NSB–1/3 Service Software Instructions Technical Documentation RSSI Reading... command Activation Status Bar Text Alt, E,E Read continuously RSSI value Command opens RSSI Reading dialog: Dialog mode: modal RSSI value is read continuously until user presses ESC–key or Close button to cancel reading. RSSI Reading dialog has following items: Close (ENTER) button: Closes the RSSI Reading dialog. Does not send anything to phone. Help button: Context sensitive help.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Self Tests... command Activation Status Bar Text Alt, E,S Open MCU Self–tests dialog box Command is used for reading self test results and running self tests. When the selection is made, the test result is read from ME. The test result will be shown to the user within MCU Self–test dialog.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Note that power–off test have no values, because if test has been passed, power has been turned off. If power–off test fails a special error message window is shown. If no response is received to power off test message in a few seconds, the user is informed by special info window, where user is asked to turn the power on and then press the return key.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Supported Self Tests The following tests are available: 1 MCU ROM Checksum................ 2 MCU RAM Interface............... 3 MCU RAM Component............... 4 MCU EEPROM Interface............ 5 MCU EEPROM Component............ 6 RTC Battery..................... 7 CCONT Interface................. 8 A/D Converter................... 9 SW Reset........................ A Power Off....................... B Security Data...................
PAMS NSB–1/3 Service Software Instructions Technical Documentation ADC Readings... command Activation Status Bar Text Alt, E,A Open ADC Readings dialog box. Command is used to read and show A/D values from phone. Command opens ADC Readings dialog. Dialog mode: modal ADC Readings dialog has static text field where measurements are updated to window every one second. ADC Readings dialog has following items: Close (ENTER) button: Closes the ADC Readings dialog. Does not send anything to phone.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Audio... command Activation Status Bar Text Alt, E, Opens a submenu which contains following options: Internal Audio Loops Activation Status Bar Text Alt, E, Open Internal Audio loops dialog box. Command is used for making internal audio loop tests in Internal Audio Loops dialog.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Internal Audio Loop group: Input group: Next two different values can be selected for input: Internal radio button (ALT+I): Turns internal input. External radio button (ALT+E): Turns external input. Headset radio button (ALT+A): Turns headset input. Output group: Next two different values can be selected for output: Internal radio button (ALT+T): Turns internal output. External radio button (ALT+X): Turns external output.
PAMS NSB–1/3 Service Software Instructions Technical Documentation User Interface... command Activation Status Bar Text Alt, E,U Open User Interface Tests dialog box Command is used for making display tests in Display Tests dialog. Dialog mode: modal Display Tests dialog has following items: 1. Test Pattern radio button (ALT+1): In test display 1 all indicators are displayed and the display is filled with chessboard letters. 2.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Dialog mode: modal Call Simulation dialog has following items: TX Power Level edit box (ALT+T): All power levels can be selected. This updates same parameter as TX Power Level in the RF Controls dialog. Note that TEST value cannot be selected. If TEST value was in use when Call simulation menu selected, power level is changed to smallest value. Channel edit box (ALT+C): This tells the normal operating RF channel number.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Noise Sensitivity... command Activation Status Bar Text Alt, E,N Opens Noise sensitivity dialog box Command is used for noise sensitivity measurement.
PAMS NSB–1/3 Technical Documentation Service Software Instructions The last value on the display is signal power difference between I and Q branch. The numbers are shown in 0.1dB accuracy. The error messages, ”OUT OF RANGE”, are shown only if the SNR and/or amplitude difference values are not acceptable. Signal/Noise radiobutton (ALT+S/ALT+N): When buttons are pressed, the RX I and Q burst data is asked, text ”SIGNAL MEASURING...” or ”NOISE MEASURING...” will come to the measurement group window.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Software Product Profile... command Activation Status Bar Text Alt, S,P Open Product Profile settings dialog box. Function is used for making product profile settings. When command is activated the product profile information is read from EEPROM and Product Profile dialog is opened. Dialog mode: modal Product Profile dialog has following items: Settings list box (ALT+E): A list where user can select desired setting.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Start Up Self–tests... command Activation Status Bar Text Alt, S,S Open MCU start Up self–tests dialog box. Function is used for changing the state of the EEPROM selectable tests in MCU Start Up Self–tests dialog. Dialog mode: modal MCU Start Up Self–tests dialog has following items: Tests list box (ALT+T): When dialog is opened, the previous values will be read from the MCU EEPROM and shown on the list box.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Set Factory Values... command Activation Status Bar Text Alt, S,V Set factory values Application does not ask confirmation. Next kind of text will be shown to user: “Setting UI and SCM Factory values...” Dialog mode: modal Default Factory Values dialog has following items: Settings list box: Contains the selectable factory values. Set button: Sets the selected factory value to phone.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Phone Identity... command Activation Status Bar Text Alt, S,I Open Phone Identity dialog box for editing Function is used to edit phone identity.
PAMS NSB–1/3 Service Software Instructions Technical Documentation This field is automatically filled, if ME is connected to the PC when dialog is loaded. Product Code edit box (ALT+P): Field where user can enter Product Code value. This field is automatically filled, if ME is connected to the PC when dialog is loaded. MS Id edit box (ALT+M): Field where user can enter MS Id corresponding programming data. This field is automatically filled, if ME is connected to the PC when dialog is loaded.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Save File... button (ALT+S): Writes a file containing data needed by security place application to create needed programming data. File is selected with File Save As dialog. Load File... button (ALT+L): Reads a file containing data needed to program selected data. File is selected with File Open dialog.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Warranty State... command Activation Status Bar Text Alt, S,W Open Warranty State dialog box This command is used to set the warranty state of a phone. When selected application opens Warranty State dialog box. Dialog mode: modal Warranty State dialog has the following items: State static text: USE For normal phones. DEFECTIVE For phones which are being swapped. A warranty and other information is transferred to the working phone.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Production Data Edit... command Activation Status Bar Text Alt, S,D Open Production Data Edit dialog box This command is used for programming HW version to phone. Function opens the following Production Data Edit dialog box. Dialog mode: modal Production Data dialog has the following items: Production Code edit box (read only): Displays production code. Order Number edit box (read only): Displays order number. Production Ser.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Flash Phone... command Activation Status Bar Text Alt, S,F Open service Flash dialog box This command is used for flashing new software into the phone. Function opens the following Flash dialog box. When flashing is started, waiting window is showed to tell the user approximated flashing time. Dialog mode: modal Flash dialog box has following items: Flash Image edit field (read only): Displays path of image file to be flashed.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Close button (ESC): Closes the dialog box and does not start flashing. Load Image... button (ALT+I): Opens Open File dialog, with which user can select a image file to be flashed to ME. If user selects OK button, the name of selected file is copied to Flash Image edit field. Load Ppm... button (ALT+P): Opens Open File dialog, with which user can select a PPM package file to be flashed to ME.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Dealer The dealer sub menu offers functions for ME settings for dealers. User Settings... command Activation Status Bar Text Alt, D,U Open User Setting dialog box This command is used to edit user settings. Dialog mode: modal User Settings dialog box has following items: Save File... button (ALT+S): User can save user settings to file. Load File button (ALT+L): User can load user settings from file. Edit...
PAMS NSB–1/3 Service Software Instructions Technical Documentation Short Code Memory... command Activation Status Bar Text Alt, D,S Open Edit SCM dialog box. This command is used for reading, storing and modifying the SIM/ME SCM values. Function opens the following Edit SCM dialog: Dialog mode: modal Edit SCM dialog has the following items: Loc static text: Display current location. Name edit box (ALT+A): Edit the Name. Number edit box (ALT+N): Edit the Number. Group edit box: Edit the Group number.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Read button (ALT+R): Read SCM values from phone. Save File... button (ALT+S): Opens a default Windows File Save As dialog and asks filename where to save SCM values. Load File... button (ALT+L): Opens a default Windows File Open dialog and asks filename where from load SCM values. Checks the validity of names and numbers. Memory group box selection: SCM memory can be defined to ME or SIM.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Loads settings from file and writes them to phone. Read Phone button (ALT+R): Reads settings from phone and writes them to file. Select File button (ALT+S): Opens Open File dialog, with which user can select the file, that contains the data to be loaded to ME or file to which data is saved from ME. If user selects OK button, the name of selected file is copied to File Name edit field. Close button (ESC): Closes the dialog box.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Post–programmable Memory... command Activation Status Bar Text Alt, D,P Open Post–programmable Memory dialog box. This command is used to load PPM from file to phone. Application checks version numbers of PPM package and ME, when file is loaded. Dialog mode: modal Post–programmable Memory dialog box has following items: ME Version edit box (read only): Shows MCU SW version string of connected phone.
PAMS NSB–1/3 Service Software Instructions Technical Documentation View Quick/RF Info... command Activation Status Bar Text Alt, V,Q View Quick/RF information. If phone is in normal mode following Quick Info is shown: If phone is in local mode following RF Information is shown. Information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Phone Information... command Activation Status Bar Text Alt, V,P View Phone Information. Command opens Phone Identity Information dialog, which shows identification information. Information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed. The After Sales Software has an initialisation file which has extension .INI. Initialisation file is TESLA.
PAMS NSB–1/3 Technical Documentation Service Software Instructions Call Simulation dialog ([NSB/E/K–3CALLSIM]) Monitoring Channel 2 (Monitoring Channel 2 =) Monitoring Channel 3 (Monitoring Channel 3 =) Monitoring Channel 4 (Monitoring Channel 4 =) Monitoring Channel 5 (Monitoring Channel 5 =) Monitoring Channel 6 (Monitoring Channel 6 =) All selections and parameters which are not same as in the RF Controls menu.
PAMS NSB–1/3 Service Software Instructions Technical Documentation Appendix 1, Vocabulary Page 66 Abreviation Description ASIC Custom circuit which for instance controls communication between MCU and DSP BBD–3 Service battery CLF Common Look and Feel CLI Calling Line Identification COBBA Common Base Band Analog DATA DATA interface module DAU–9S/P MBUS/FBUS cable DLL Dynamic Link Library DSP Digital Signal Processor which controls radio interface and speech coding/decoding EEPROM Me
PAMS NSB–1/3 Service Software Instructions Technical Documentation PC IBM PS/AT or compatible personal computer PCI Phone Controlling Interface SW for PC PKD–1/1NS/1CS Hardware protection key (DESKEY DK2) for protecting service software from illegal copying.
PAMS NSB–1/3 Service Software Instructions Technical Documentation This page intentionally left blank.