User Guide

PAMS
Technical Documentation
NSB–1/3
Tuning Instructions
Page 14
Original 06/98
3. Tuning of Transmitter Power Levels
This adjustment loads the power levels of the phone transmitter into the
EEPROM. When doing this, a pulse power meter or spectrum analyzer
must be used.
Adjust spectrum analyzer centre frequency to 1880 MHz, Span 0 Hz,
Res BW 3 MHz, Video BW 3MHz, Sweep time <20ms and Marker
peak.
Power levels programming:
Set power supply voltage 8.4 V to service battery (or 3.6 V to jig).
Connect pulse power meter or spectrum analyzer (with an attenuator if
needed) to the external antenna connector of the phone.
Select
Tuning –> TX Power...
Select tuning values from the PC’s memory, the phone’s EEPROM or
factory default values.
Check that the channel is 661.
If it doesn’t, change it in RF Controls window.
Increase base value by:
0.005 for SW version 3.X
0.012 for SW version 4.00 or later
Adjust the power level (levels 0, 7, 8 and 15) by clicking the
+ and – buttons or and keys, and change levels with
and
keys.
Power
level
Tuning P
OUT
/dBm
(CH 661)
Note: attenuation!!
0 29,5
7 16.0
8 14.0
15 0
Press
Calculate
button to calculate all other levels.
Once all TX levels are correct, press
SAVE
button.