User Guide

PAMS
Technical Documentation
NSB–1/3
Tuning Instructions
Page 12
Original 06/98
2. I/Q Modulator Amplitude Balance and Phase Shift Tuning
The purpose of this tuning operation is to adjust the I/Q modulator d.c. off-
sets and the I/Q modulator amplitude balance and phase shift.
I/Q modulator d.c. offsets, amplitude balance and phase shift tuning:
Connect spectrum analyzer (with an attenuator if needed) to the exter-
nal antenna connector of the phone.
Select
Tuning –> TX I/Q...
Select I/Q tuning values from the PC’s memory, the phone’s EEPROM
or factory default values.
Check that the channel is 661 and the TX Data Type is Cont1.
If it doesn’t, change it in RF Controls window.
Adjust spectrum analyzer centre frequency to 1880 MHz, Span 200
kHz, Res BW 10 kHz, Video BW 1 kHz and Sweep time 0.5 s – 1s.
–67.71 kHz +67.71 kHz
CHF
> 30 dB
> 35 dB
Set this value
to minimum
Amplitude &
phase difference:
Set this value
to minimum
D.C. offset
tunings:
Select the ”TX I d.c. offset” option.
Adjust the level of centre frequency (CHF signal) to minimum by vary-
ing D/A converter value with
<–
and
–>
buttons.
The amplitude difference between CHF–67.7 kHz and CHF should be
>30 dB.
Select option ”TX Q d.c. offset”.
Adjust the level of signal CHF to minimum by varying D/A converter
value with
<–
and
–>
keys.