User Guide

Nokia Customer Care Troubleshooting Instructions
Company confidential NPL-4/5
Issue 1 05/04 Copyright © 2004 Nokia Corporation. All rights reserved. Page 19
Figure 9: Signal Measurement
- Choose the remaining GSM bands and measure accordingly the procedure described
above.
Measuring front-end power levels using spectrum analyzer
Spectrum Analyzer (SA) level values depend on the probe type and shall be verified by a
properly working phone sample.
- Start Phoenix Service Software and open FBUS connection.
- Select Scan Product (Ctrl-R)
Wait until phone information is shown in the lower right corner of the screen.
- Set operating mode to “local mode
- Select Testing RF Controls
- Select Band GSM850 or GSM 900 or GSM1800 or GSM1900
Active unit RX
Operation mode Continuous
RX/TX Channel 190 or 37 or 700 or 661