User Guide
Nokia Customer Care
NPL-4/5
Issue 1 05/04 Copyright ©2004 Nokia Corporation. All rights reserved.. Page 39
Figure 3: RX Calibration Setup
- Press “Start”: The current calibration values are loaded from the phone memory and
displayed in the window “PM values” and a window pops up, instructing you on fre-
quency and power level tuning of the RF signal generator:
1 ) Power Level: -60 dBm
2 ) Frequency: 881.667110 MHz (GSM 850) or
942.467110 MHz (GSM 900)
- Compensate for external RF cable and test jig losses.
If a radio communication tester (CMD 55, CMU 200, HP 8960, MT 8801) is used, assure
that “continuous mode” is switched on and “modulation” switched off.
- Press “OK” and the calibration will be executed.
- Press “Save and continue” to calibrate GSM1800 and GSM1900
Typical calibration values will look like this: