annel edit box (ALT+H):
User can enter here channel number that is used for both transmission
and receiving. The frequency of the selected channel is shown after
selection.
Monitoring Channel edit box (ALT+M):
This field selects neighbour monitoring channel. The frequency of the se-
lected channel is shown after selection.
Continuous Mode Channel edit box (ALT+C):
To this edit box user can type continuous mode channel which may have
all channel numbers.
The used frequency depends on the Active Unit. If Active Unit is RX, then
RX frequency is used, else TX frequency. The frequency of the selected
channel is shown after selection.
AGC A
bsolute edit box (ALT+A):
This selection allows user to edit AGC absolute value (value from A/D
converter).
When AGC Absolute value is changed the AGC dB value will be calcu-
lated depending on the AGC Absolute value.
Front End On check box:
This selection allows user to change whether the Front End amplifier is
On or Off.
AGC edit box (ALT+G):
This selection allows user to edit AGC absolute value (value from A/D
converter).
AGC value is shown only when its value is controlled by PC. When Active
Unit has value RX and Operation Mode is continuous, AGC is controlled
by PC except when next adjustment functions are activated:
RSSI Calibration
AFC Diagram
Apply button (ALT+A):
Accepts entered values and validates them. After validation application
sends corresponding messages to ME. Closes dialog and updates Info
Window.
Note! Active Unit and Operation mode are not send with because they are
activated immediately.
Set Defaults button (ALT+S):
Sets current values as default Rf Controls values.
Get Defaults button (ALT+G):
Gets default Rf Controls values as current values.
The next automatic selection is made when Quick testing function is ended: