User Guide

CCS Technical Documentation
NPM-6/6X
Issue 2 06/03 Copyright Nokia. All rights reserved.. Page 61
Tune wrong sideband to minimum using Amplitude/Phase difference controls (f0+68kHz
on spectrum analyzer screen)
Choose “Stop” to end tuning at the EGSM900 band when vales are within limits.
Continue tuning from GSM1800. Choose the correct band from the dropdown menu
Choose “Start” to begin tuning.
Repeat the same tuning steps as for the EGSM900 band.
Set spectrum analyzer center frequency to 1747.8 MHz, span 200kHZ, RBW and VWB
3kHz and sweeptime to 2 seconds.
Continue tuning from GSM1900. Choose the correct band from the dropdown menu.
Repeat the same steps as for the EGSM900 and GSM1800 bands.
Set spectrum analyzer center frequency to 1880.0 MHz, span 200kHZ, RBW and VWB
3kHz and sweeptime to 2 seconds
A_wr i t eB_bl ank
CENTER 897. 4000 MHz SPAN 200. 0 kHz
2. 0 s
SWP
3kHz
VBW
3kHz
RBW
10dB/
REF 32 . 0 dBm ATT 40 d B
GSMPOW Thu Aug 30 11: 43: 45 2001
REF OF S