User Guide
Table Of Contents
- Amendment Record Sheet
- Copyright
- Warnings and cautions
- For your safety
- Care and maintenance
- ESD protection
- Battery information
- Company Policy
- Nokia 3610 fold Service Manual Structure
- 1 General information
- 2 Service Tools and Service Concepts
- 3 BB Troubleshooting and Manual Tuning Guide
- General BB troubleshooting guidelines
- Phoenix self tests
- ST_CURRENT_CONS_TEST troubleshooting
- ST_SLEEPCLK_FREQ_TEST troubleshooting
- ST_SLEEP_X_LOOP_TEST troubleshooting
- ST_UEM_CBUS_IF_TEST troubleshooting
- Power and charging troubleshooting
- Interface troubleshooting
- User interface troubleshooting
- Camera module troubleshooting
- Audio troubleshooting
- Bluetooth troubleshooting
- Baseband manual tuning guide
- 4 RF troubleshooting
- 5 System Module
- Glossary

vii To write the file to phone, click Start.
Next actions
After a successful rewrite, you must retune the phone completely by using
Phoenix
tuning functions.
Important: Perform all tunings: RF, BB, and UI.
Energy management calibration
Prerequisites
Energy Management (EM) calibration is performed to calibrate the setting (gain and offset) of AD converters
in several channels (that is, battery voltage, BSI, battery current) to get an accurate AD conversion result.
Hardware setup:
• An external power supply is needed.
• Supply 12V DC from an external power supply to CU-4 to power up the phone.
• The phone must be connected to a CU-4 control unit with a product-specific flash adapter.
Steps
1. Place the phone to the docking station adapter (CU-4 is connected to the adapter).
2. Start
Phoenix
service software.
3. Choose File→ Scan Product.
4. Choose Tuning→Energy Management Calibration.
5. To show the current values in the phone memory, click Read, and check that communication between
the phone and CU-4 works.
6. Check that the CU-4 used check box is checked.
7. Select the item(s) to be calibrated.
Note: ADC calibration has to be performed before other item(s). However, if all calibrations are
selected at the same time, there is no need to perform the ADC calibration first.
8. Click Tune.
The calibration of the selected item(s) is carried out automatically.
The candidates for the new calibration values are shown in the
Calculated values
column. If the new
calibration values seem to be acceptable (please refer to the following "Calibration value limits" table),
click Write to store the new calibration values to the phone permanent memory.
RM-429
BB Troubleshooting and Manual Tuning Guide
Page 3 –54 COMPANY CONFIDENTIAL Issue 1
Copyright © 2008 Nokia. All rights reserved.