User Guide
Table Of Contents
- Amendment Record Sheet
- Copyright
- Warnings and cautions
- For your safety
- Care and maintenance
- ESD protection
- Battery information
- Company Policy
- Nokia 3610 fold Service Manual Structure
- 1 General information
- 2 Service Tools and Service Concepts
- 3 BB Troubleshooting and Manual Tuning Guide
- General BB troubleshooting guidelines
- Phoenix self tests
- ST_CURRENT_CONS_TEST troubleshooting
- ST_SLEEPCLK_FREQ_TEST troubleshooting
- ST_SLEEP_X_LOOP_TEST troubleshooting
- ST_UEM_CBUS_IF_TEST troubleshooting
- Power and charging troubleshooting
- Interface troubleshooting
- User interface troubleshooting
- Camera module troubleshooting
- Audio troubleshooting
- Bluetooth troubleshooting
- Baseband manual tuning guide
- 4 RF troubleshooting
- 5 System Module
- Glossary

PCS-1 Power cable
The PCS-1 power cable (DC) is used with a docking station, a module
jig or a control unit to supply a controlled voltage.
XCS-4 Modular cable
XCS-4 is a shielded (one specially shielded conductor) modular cable
for flashing and service purposes.
XRS-6 RF cable
The RF cable is used to connect, for example, a module repair jig to
the RF measurement equipment.
SMA to N-Connector approximately 610 mm.
Attenuation for:
• GSM850/900: 0.3+-0.1 dB
• GSM1800/1900: 0.5+-0.1 dB
• WLAN: 0.6+-0.1dB
Attenuation values for SA-130
Band Channel Freq. Attenuation RX Freq. Attenuation TX
GSM 850
Low 869.2 -13.4 824.2 -15.5
Mid 881.6 -12.5 836.6 -15
High 893.8 -11.7 848.8 -14.2
RM-429
Service Tools and Service Concepts
Issue 1 COMPANY CONFIDENTIAL Page 2 –15