- 1 General information
- 2 Service Tools and Service Concepts
- 3 BB Troubleshooting and Manual Tuning Guide
- General BB troubleshooting guidelines
- Phoenix self tests
- ST_CURRENT_CONS_TEST troubleshooting
- ST_SLEEPCLK_FREQ_TEST troubleshooting
- ST_SLEEP_X_LOOP_TEST troubleshooting
- ST_UEM_CBUS_IF_TEST troubleshooting
- Power and charging troubleshooting
- Interface troubleshooting
- User interface troubleshooting
- Camera module troubleshooting
- Audio troubleshooting
- Bluetooth troubleshooting
- Baseband manual tuning guide
- 4 RF troubleshooting
- 5 System Module
- Glossary

Normal and extreme voltages
Energy management is mainly carried out in the two Application Specific Integrated Circuits (ASICs) N2300
BETTY and N2200 AVILMA. These two circuits contains a number of regulators. In addition there are some
external regulators too.
In the table below normal and extreme voltages are shown when a BL-5C battery is used.
Table 10 Nominal voltages
Voltage Voltage [V] Condition
General Conditions
Nominal voltage 3.700
Lower extreme voltage 3.145
Higher extreme voltage
4.230(fast charging)
HW Shutdown Voltages
Vmstr+ 2.1 ± 0.1 Off to on
Vmstr- 1.9 ± 0.1 On to off
SW Shutdown Voltages
Sw shutdown 3.1 In call
Sw shutdown 3.2 In idle
Min Operating Voltage
Vcoff+ 2.9 ± 0.1 Off to on
Vcoff- 2.6 ± 0.1 On to off
Power key and system power-up
When the battery is placed in the phone the power key circuits are energized. When the power key is pressed,
the system boots up (if an adequate battery voltage is present).
Power down can be initiated by pressing the power key again (the system is powered down with the aid of
SW). The power key is connected to EM ASIC N2200 (AVILMA) via PWRONX signal.
Modes of operation
Mode Description
NO_SUPPLY (dead) mode means that the main battery is not present or its voltage is too low (below
N2200 AVILMA master reset threshold) and that the back-up battery voltage is too low.
BACK_UP The main battery is not present or its voltage is too low but back-up battery voltage is
adequate and the 32 kHz oscillator is running (RTC is on).
PWR_OFF In this mode (warm), the main battery is present and its voltage is over N2300 BETTY
master reset threshold. All regulators are disabled, PurX is on low state, the RTC is on
and the oscillator is on. PWR_OFF (cold) mode is almost the same as PWR_OFF (warm),
but the RTC and the oscillator are off.