User Guide

Table Of Contents
General RF troubleshooting
Introduction to RF troubleshooting
Most RF semiconductors are static discharge sensitive
ESD protection must be applied during repair (ground straps and ESD soldering irons).
Pre-baking
These parts are moisture sensitive and must be pre-baked prior to soldering:
RF IC N7505
TXFEM N7520
DC/DC Converter N7590
Tx Saw GSM 850/900 Z7503
Rx Saw GSM 1800/1900 Z7501
Note: Please review the appropriate process for storage and handling of these components prior
to soldering.
Discrete components
In addition to the key-components, there are a number of discrete components (resistors, inductors and
capacitors) for which troubleshooting is done mainly by
visual inspection
.
Capacitors: check for short circuits.
Resistors: check value with an ohm meter.
Note: In-circuit measurements should be evaluated carefully
Measuring equipment
All measurements should be done using:
An oscilloscope for low frequency and DC measurements. Recommended probe: 10:1, 10Mohm//8pF.
A radio communication tester including RF generator and spectrum analyser, for example Rohde & Schwarz
CMU200. (Alternatively a spectrum analyser and an RF generator can be used. Some tests in this guide are
not possible to perform if this solution is chosen).
Note: All measurements with an RF coupler should be performed in an RF-shielded environment
because nearby base stations can disturb sensitive receiver measurements. If there is no possibility
to use RF shielded environment, testing at frequencies of nearby base stations should be avoided.
Level of repair
The scope of this guideline is to enable repairs at key-component level. Some key-components are not
accessible, i.e. not replaceable. Please refer to the list of Non-replaceable RF components (page 4–6).
RM-429
RF troubleshooting
Issue 1 COMPANY CONFIDENTIAL Page 4 –5
Copyright © 2008 Nokia. All rights reserved.