User Guide
Table Of Contents
- Amendment Record Sheet
- Copyright
- Warnings and cautions
- For your safety
- Care and maintenance
- ESD protection
- Battery information
- Company Policy
- Nokia 3610 fold Service Manual Structure
- 1 General information
- 2 Service Tools and Service Concepts
- 3 BB Troubleshooting and Manual Tuning Guide
- General BB troubleshooting guidelines
- Phoenix self tests
- ST_CURRENT_CONS_TEST troubleshooting
- ST_SLEEPCLK_FREQ_TEST troubleshooting
- ST_SLEEP_X_LOOP_TEST troubleshooting
- ST_UEM_CBUS_IF_TEST troubleshooting
- Power and charging troubleshooting
- Interface troubleshooting
- User interface troubleshooting
- Camera module troubleshooting
- Audio troubleshooting
- Bluetooth troubleshooting
- Baseband manual tuning guide
- 4 RF troubleshooting
- 5 System Module
- Glossary

General RF troubleshooting
Introduction to RF troubleshooting
Most RF semiconductors are static discharge sensitive
ESD protection must be applied during repair (ground straps and ESD soldering irons).
Pre-baking
These parts are moisture sensitive and must be pre-baked prior to soldering:
• RF IC N7505
• TXFEM N7520
• DC/DC Converter N7590
• Tx Saw GSM 850/900 Z7503
• Rx Saw GSM 1800/1900 Z7501
Note: Please review the appropriate process for storage and handling of these components prior
to soldering.
Discrete components
In addition to the key-components, there are a number of discrete components (resistors, inductors and
capacitors) for which troubleshooting is done mainly by
visual inspection
.
Capacitors: check for short circuits.
Resistors: check value with an ohm meter.
Note: In-circuit measurements should be evaluated carefully
Measuring equipment
All measurements should be done using:
• An oscilloscope for low frequency and DC measurements. Recommended probe: 10:1, 10Mohm//8pF.
• A radio communication tester including RF generator and spectrum analyser, for example Rohde & Schwarz
CMU200. (Alternatively a spectrum analyser and an RF generator can be used. Some tests in this guide are
not possible to perform if this solution is chosen).
Note: All measurements with an RF coupler should be performed in an RF-shielded environment
because nearby base stations can disturb sensitive receiver measurements. If there is no possibility
to use RF shielded environment, testing at frequencies of nearby base stations should be avoided.
Level of repair
The scope of this guideline is to enable repairs at key-component level. Some key-components are not
accessible, i.e. not replaceable. Please refer to the list of Non-replaceable RF components (page 4–6).
RM-429
RF troubleshooting
Issue 1 COMPANY CONFIDENTIAL Page 4 –5
Copyright © 2008 Nokia. All rights reserved.