User Guide

NPM-10 (3595)
System Module CC Technical Documentation
Page 36 ©2004 Nokia Corporation Confidential Issue 2 03/2004
The device supports reads and in-system erase, and program operations at Vcc=1.8 V
(Voltage range 1.7 V -1.9 V). Flashing at production is supported at Vpp=12 V (for limited
exposure length only).
Test Interfaces
Through MBUS or FBUS connections, the phone HW can be tested through the Phoenix
service software.
Service Interface
Figure 10: Production/Test/Customer Care interface
RF Module
This section describes the blocks of the RF engine, the RF requirements, and the environ-
mental requirements for the NPM-10 (3595) RF engine.
GENTEST0
(DAI Clock)
MBUS
FBUSTX
VPP
GND
FBUSRX