Page 6 ©2004 Nokia Corporation Confidential Issue 2 03/2004
Flash Programming Does Not Work
The flash programming can only be done via the pads on the PWB (J100).
In case of flash failure in FLALI station, the problem is most likely related to SMD
problems. Possible failures could be short-circuit of balls under µBGAs (UEM, UPP,
FLASH), or missing or misaligned components.
In flash programming error cases, the flash prommer can give some information about a
fault. The fault information message could be “Phone doesn't set FBUS_TX line low”.
Because of the use of uBGA components, it is not possible to verify if there is a short
circuit in control- and address lines of MCU (UPP) and memory (flash).
Figure 3: Flash programming does not work
Flash programming
does not work
Error from prommer:
“Phone doesn’t set FBUS_TX
line low.
J100, R108
Check connection between
pad 1, 2 and 3 on J100 and
R108
J409, J410, J411, J412
Voltage level at 1.8 VDC
Try reading MCU ID
with Phoenix:
Reading OK?
Try reading flash ID
with Phoenix:
Reading OK?
Yes
Yes
Yes
Yes
Yes
CHECK:
R108, PWB
No
No
No
No
CHECK:
PWB, else defective D200
CHECK:
PWB, else defective D400
CHECK:
Replace D450
Reflash the phone