User Guide

NHM-8NX
System Module & UI PAMS Technical Documentation
Page 78 ãNokia Corporation Issue 1 05/02
Output power requirements, GSM1800
Table 40: Output power requirements, GSM1800
Output modulation spectrum - E-GSM
Table 41: Output RF spectrum due to modulation, requirements, E-GSM
Output modulation spectrum - GSM1800
Output power tolerance
(power level 5)
+/- 2.0
+/- 2.5
dB, normal cond.
dB, extreme cond.
Output power tolerance
(power levels 6...15)
+/- 3.0
+/- 4.0
dB, normal cond.
dB, extreme cond.
Output power tolerance
(power levels 16...19)
+/- 5.0
+/- 6.0
dB, normal cond.
dB, extreme cond.
Output power control step size 0.5 2.0 3.5 dB
Output Power requirements - GSM1800
Parameter Min Typ Max Unit / Notes
Max. output power 30.0 DBm
Output power tolerance
(power level 0)
+/- 2.0
+/- 2.5
DB, normal cond.
DB, extreme cond.
Output power tolerance
(power levels 1...8)
+/- 3.0
+/- 4.0
DB, normal cond.
DB, extreme cond.
Output power tolerance
(power levels 9...13)
+/- 4.0
+/- 5.0
DB, normal cond.
DB, extreme cond.
Output power tolerance
(power levels 14...15)
+/- 5.0
+/- 6.0
DB, normal cond.
DB, extreme cond.
Output power control step size 0.5 2.0 3.5 DB
Output modulation spectrum - E-GSM
Power
level
100 kHz 200 kHz 250 kHz 400 kHz 600 to
1800
kHz
1800 to
3000
kHz
3000 to
6000
kHz
> 6000
kHz
Unit
Measurements BW: 30 kHz Measurements
BW: 100 kHz
< 33 dBm +0.5 -30 -33 -60 -60 -63 -65 -71 dBc
Minimum
abs. Level
-36 -36 -36 -36 -38 -51 -46 -46