CCS Technical Documentation NEM-2 Series Transceivers Service Tools Issue 1 07/03 Nokia Corporation
NEM-2 Service Tools CCS Technical Documentation [This page left intentionally blank] Page 2 Nokia Corporation Issue 1 07/03
NEM-2 Service Tools CCS Technical Documentation Table of contents FLA-36 POS (Point Of Sales) Flash Loading Adapter.................................................. 5 Product Code ...............................................................................................................5 View of FLA-36 ........................................................................................................ 5 MJ-6 Module Test Jig .........................................................................
NEM-2 Service Tools CCS Technical Documentation XRS-6 RF Cable .......................................................................................................... 23 Product code .............................................................................................................23 View of XRS-6........................................................................................................ 23 CA-5S DC Cable.............................................................................
NEM-2 Service Tools CCS Technical Documentation FLA-36 POS (Point Of Sales) Flash Loading Adapter FLA-36 POS Flash Loading Adapter is used in place of the phone's normal battery during service to supply a controlled operating voltage. It works only in connection with flashing tools FPS-8 or FLS-4. The adapter is equipped with pins which will contact the necessary test pattern on the PWB. Power supply is handled either with FLC-2 or with XCS-1.
NEM-2 Service Tools CCS Technical Documentation MJ-6 Module Test Jig A module jig is designed to hold the main PWB and the UI module when covers are removed and component level troubleshooting / diagnostic are done. Note! No RF tuning allowed with MJ-6.
NEM-2 Service Tools CCS Technical Documentation Additional UI parts for NEM-2 and MJ-6: 0201970 EM20 UI PWB ASSY 4850265 LCD MODULE 130X130 COF CSTN 4KCO 9460588 KEY GUIDE ASSY For AMS 9460541 R1011-LIGHTGUIDE 9511052 LCD METAL FRAME 5140067 SPEAKER+SPRING 105+-3DB 32R D13.
NEM-2 Service Tools CCS Technical Documentation JXS-2 Shield box JXS-2 Shield box is used for RF tuning and with DA-1 Docking adapter. Note! JBV-1 stays outside the JXS-2 RF shielded chamber.
NEM-2 Service Tools CCS Technical Documentation DA-1 Docking Adapter Docking adapter is designed to hold the assembled phone for low level troubleshooting / diagnostics. A RF-coupler is integrated in the Docking station adapter. Note! Tuning only with DA-1 inside JXS-2.
NEM-2 Service Tools CCS Technical Documentation MJS-74 Soldering Jig MJS-74 Soldering Jig is used for soldering and as a rework jig for NEM- 2 module.
NEM-2 Service Tools CCS Technical Documentation DKU-2 Bottom connector-USB cable DKU-2 cable is used for ADSP Flashing and for some testing in NEM-2.
NEM-2 Service Tools CCS Technical Documentation JBV-1 Docking station The Docking station JBV-1 is used as the basic adapter for the Docking station adapter and is different for each product. It includes electronic parts and common interfaces. Note that the picture below describes JBV-1 connected to MJF-22.
NEM-2 Service Tools CCS Technical Documentation FPS-8 Flash Prommer (Sales Pack) The Flash Prommer FPS-8 is used with e.g. MJF-22 and JVB-1. Power is supplied to FPS-8 from the Universal Power Supply.
NEM-2 Service Tools CCS Technical Documentation FPS-8C Parallel Flash Prommer (Sales Pack) The Parallel Flash Prommer FPS-8C is used with MJF-22 and JVB-1. Flash programming can be done to maximum of 8 phones parallel. FPS-8C consists of eight SF11C programming cards. SF11C card is functionally identical to FPS-8.
NEM-2 Service Tools CCS Technical Documentation FLS-4S POS (Point Of Sales) Flash Device (Sales Pack) FLS-4S is a dongle and flash device incorporated into one package and developed specifically for POS use.
NEM-2 Service Tools CCS Technical Documentation PKD-1 SW Security Device SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
NEM-2 Service Tools CCS Technical Documentation DAU-9S MBUS Cable The MBUS Cable DAU-9S has a modular connector and is used between PC's serial port and e.g. Module Jig MJS-38.
NEM-2 Service Tools CCS Technical Documentation XCS-1 Service Cable The XCS-1 Service Cable is used to connect FLS-4 to FLA-27.
NEM-2 Service Tools CCS Technical Documentation ACF-8 Universal Power Supply ACF-8 Universal Power Supply is used to power FPS-8. ACF-8 has 6 V DC and 2.1 A output.
NEM-2 Service Tools CCS Technical Documentation FLC-2 DC Cable The FLC-2 is used to supply a controlled operating voltage.
NEM-2 Service Tools CCS Technical Documentation AXS-4 Service Cable The AXS-4 D9-D9 Service Cable is used to connect two 9 pin D connectors e.g. between PC and FPS-8. Cable length is 2 meters.
NEM-2 Service Tools CCS Technical Documentation PCS-1 Power Cable The PCS-1 Power Cable (DC) is used to connect e.g. JVB-1 to FPS-8.
NEM-2 Service Tools CCS Technical Documentation XRS-6 RF Cable RF cable XRS-6 is used to connect e.g. Module Jig MJS-38 to RF measurement equipment.
NEM-2 Service Tools CCS Technical Documentation CA-5S DC Cable The DC cable CA-5S is used to connect e.g. JBV-1 to the phone for EM calibration.
NEM-2 Service Tools CCS Technical Documentation XCS-4 Modular Cable XCS-4 is a shielded cable (one specially shielded conductor) modular cable for flashing and service purposes.
NEM-2 Service Tools CCS Technical Documentation Printer Cable This cable is used to connect the PC to FPS-8.
NEM-2 Service Tools CCS Technical Documentation SK-5 LGA component rework kit The kit is used for FM-radio component.
NEM-2 Service Tools CCS Technical Documentation SK-6 LGA component rework kit The kit is used for PA.