User Guide
Item Description Type Code
SRAM Module (3 pcs
needed inside FPS-8)
SF-12 0080346 (Code includes
one SRAM module)
Note: More than 32MB SRAM required in FPS-8.
Module jig service concept
This concept is for troubleshooting and RF calibration.
MJ-55 is intended for use with an external power supply.
MJ-55 input voltage: normal +4 V, maximum +6.5 V.
Ensure that the jumper is set for voltage regulation before the external power supply is connected.
When FPS-8 is used as the power supply (4 V), the jumper should be set to bypass regulator.
EM calibrations including Zocus are only done with JBV-1. Module jig MJ-55 does not support Zocus calibration.
Figure 80 Module jig service concept
Item Description Type Code
1 Module jig MJ-55 0780413
2 RF cable XRF-1 0730085
3 Power cable PCS-1 0730012
4 MBUS cable DAU-9S 0730108
5 Software protection key PKD-1 0750018
6 Computer with Phoenix
SSW
JBV-1 service concept
This concept is for BB calibration.
EM calibration including Zocus should be carried out in JBV-1 and DA-44.
RM-51
Service Tools Nokia Customer Care
9238460 (Issue 1) Company Confidential Page 4–25