User Guide
PAMS
Technical Documentation
NSE–8/9
Troubleshooting
Page 19
Issue 1 07/99
Card rejected fault
VSIM according
to spec.
2.8Vmin (3V card) 3,2Vmax
4.5Vmin (5V card) 5,2Vmax
Faulty PCB, N100
No
ATR data can be
seen at C140
Check X100, R115
ATR data can be seen
at J325 on D300
No
Yes
Yes
Check N100
SIM_IOControl line (J322)
on D300 is ”1” during ATR
message
Check D300
Check N100
No
Yes
No
Yes
Figure 4–14