User Guide

PAMS
Technical Documentation
NSE 8/9
Service Software Instructions
Page 7
Issue 1 07/99
Equipment Setup
Caution: Make sure that you have switched off the PC and the printer
before making connections !
Caution: Do not connect the PKD–1 key to the serial port. You may
damage your PKD–1 !
Attach the protection key PKD–1 to parallel port one (25–pin female
D–connector) of the PC. When connecting the PKD–1 to the parallel port
be sure that you insert the PC end of the PKD–1 to the PC (male side). If
you use a printer on parallel port one, place the PKD–1 between the PC
and your printer cable.
Next connect the M2BUS service cable, DAU–9P, to the serial port
(RS–232) of the computer. Attach one end of the service cable to the PC
serial port and the other end to TDS–7 or MJS–13.
When the phone covers are removed the jigs should be used.
For audio measurements connect the audio cable, SCB–5 from the
bottom connector on the phone, or MJS–13, to service box JBA–4.
For JBA–4 and ADS–1 connect as follows:
– EAR line to AF INPUT of test equipment
– MIC line to MOD GEN OUTPUT of test equipment