User Guide

PAMS
Technical Documentation
NSE 8/9
Service Software Instructions
Page 39
Issue 1 07/99
AGC edit box (ALT+G):
This selection allows user to edit the AGC dBvalue. The AGC value is
shown only when its value is controlled by PC. When Active Unit has
value RX and Operation Mode is continuous, AGC is controlled by PC
except when next adjustment functions are activated:
RSSI Calibration
AFC Diagram
Apply button (ALT+A):
Accepts entered values and validates them. After validation all values are
sent to ME and the RF information window is updated.
Note! Active Unit and Operation mode are not included because they are activated
immediately.
Set Defaults button (ALT+S):
Sets current values shown as default RF Controls values. Stores the
values in
Tesla.ini
Get Defaults button (ALT+G):
Gets default RF Controls values from the
Tesla.ini
file and shows them.
The next automatic selection is made when Quick testing function is
ended:
Active Unit = RX
Update RF Information window
The next table shows the dialog’s properties on different situations:
ACTIVE UNIT = TX:
TX Data Type: Updated
AGC values: Greyed
Monitoring Channel: Greyed
OPERATION MODE = BURST:
TX Power Level: Updated
Continuous Mode Channel: Greyed
Channel: Updated
ACTIVE UNIT = RX:
TX Data Type: Greyed
TX Power Level: OFF, Greyed