User Guide
PAMS
Technical Documentation
NSE 8/9
Service Software Instructions
Page 28
Issue 1 07/99
The TX Power Tuning dialog will be activated automatically after value
selection.
Dialog mode: modal
TX Power Tuning dialog has following items:
Power Level & Coefficients list box (ALT+L):
The power is presented in GSM or PCN values. The test value is not
saved to the EEPROM. The test value can be changed during tuning as
other power coefficients and the program remembers its value when
tuning function is activated later again.
If there is more power levels in the phone that can fit into window the
window is scrollable. When phone is initialised the program asks the
number of power levels used in the phone.
Only three power coefficients (highest, third smallest and lowest) are
needed to tune (left justified Coefficients) and the rest of them are
calculated.
The highlighted tuning position can be tuned with +/– keys or left/right
cursor keys.
Calculate button (ALT+C):
The calculation is activated with this button. The power coefficients which are
calculated from the tuned coefficients are displayed.