PAMS Technical Documentation NSE 8/9 Series Transceivers Service Software Instructions Issue 1 07/99
PAMS NSE 8/9 Service Software Instructions Technical Documentation CONTENTS Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 3.1x . . . . . . . . . . . . . . . . . . . . . . . . Hardware requirements for Windows 95 . . . . . . . . . . . . . . . . . . . . . . . . . . Software Environment of the Support Modules . . . . . . . . . . . . . . . . . . . . Required Servicing Equipment . . . . . . . . . . . . . . . .
PAMS NSE 8/9 Technical Documentation Service Software Instructions Tx Power... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Tx I/Q... command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Energy Management Calibration... command . . . . . . . . . . . . . . . . . . 32 DC/DC Tuning Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Testing . . . . . . . . . . . . . . . . . . . . . . .
PAMS NSE 8/9 Service Software Instructions Technical Documentation [This page intentionally left blank] Page 4 Issue 1 07/99
PAMS NSE 8/9 Technical Documentation Service Software Instructions Installing the Software To run the After Sales SW, a parallel port software protection device (PKD–1) has to be connected. TDF–4 box must be connected to the PC for flashing purposes. The user can use PC–locals functions in modules for testing NSE–8 mobile stations (MS).The test functions send test messages from PC to MS and receive results and show them in the PC display. The messages can be sent via M2BUS or FBUS.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Required Servicing Equipment – Computer: At least IBM 80386 or compatible with one unused serial port (COM1 or COM2) *), one parallel port (LPT1), hard disk recommended – Operating System: DOS Version 3.2 or later – If PCLStart in use: DOS 6.22 and IBM 80486 or compatible – Display: Any 80–character text display – Service software version for 3.
PAMS NSE 8/9 Technical Documentation Service Software Instructions Equipment Setup Caution: Make sure that you have switched off the PC and the printer before making connections ! Caution: Do not connect the PKD–1 key to the serial port. You may damage your PKD–1 ! Attach the protection key PKD–1 to parallel port one (25–pin female D–connector) of the PC. When connecting the PKD–1 to the parallel port be sure that you insert the PC end of the PKD–1 to the PC (male side).
PAMS NSE 8/9 Service Software Instructions Technical Documentation Installing the Software on PC Hard Disk The program is delivered on a diskette and is copy protected with a dongle PKD–1. It must be present in parallel port when using Service software. The program can also be installed on the hard disk, which is recommendable to obtain a maximum data access rate.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Equipment Setup for Tuning a Phone without Removing Covers 6 4. 1 5. 2 3. Item: code: Service accessory: Product 1 Service Interface Cable TDS–7 0770160 2 DC Cable PCS–1 0730012 3 Service MBUS Cable 4 Software Protection Key PKD–1 0750018 5 Service SW Disk 3.
NSE–8/9 PAMS Service Software Technical Documentation Flash Concept for NSE–8/9 (covers on) 10. 13. 12. 11. 6. 9A. 5. 7. 4. 8. 9B. 1. 14 2. 3.
PAMS NSE–8/9 Technical Documentation Service Software Flash Concept for NSE–8/9 (covers off) 10. 4. 12. 13. 11. 6. 9A. 5. 7. 9B. 1. 14 2. 3.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Tuning With Covers Off 4 8. 9. 1. 3. 6. 7. 5. 2. Item: Service accessory: Product code: 1 Module Jig MJS–13 0770158 2 Service Audio Box JBA–4 0770094 3 DC Cable PCS–1 0730012 4 RF Coaxial Test Cable 4626009 5 Audio Test Cable SCB–5 0775211 6 Service MBUS Cable DAU–9S 0730108 7 Audio Cable ADS–1 0730011 8 Software Protection Key PKD–1 0750018 9 Service SW diskette 3.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Warranty Transfer 2 1 Item: Service accessory: Product code: 1 Warranty Transfer Tool SCW–1 0770161 (2pcs reqd.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Tuning Steps 1. RX Calibration (AGC + AFC) Procedure Follow the steps described in chapter ”Service Software Instructions” section ”RX calibration... command”.
PAMS NSE 8/9 Technical Documentation Service Software Instructions If the RSSI reading seems to be within 5 - 10 dB the same as the RF input level check that the VCTCXO (G650) frequency is close enough the wanted frequency. This is most easiest done by measuring the UHF VCO (G550) frequency because the absolute value of the deviation is biggest there. In the GSM mid channel the UHF–VCO frequency should be 2040.0 MHz.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Targets in dBm: ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ ÁÁÁÁÁÁÁÁ
PAMS NSE 8/9 Technical Documentation Service Software Instructions 3. I/Q Modulator Alignments I/Q modulator alignments are performed in PCN band. If GSM band has been selected and I/Q alignment is started, the service software asks to change to PCN band. If the user wants to continue in GSM, the adjusted values can only be saved to PC memory, not to phone’s EEPROM.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Alignment verification in GSM band: – Go to Product ––> Initialize ––> Normal mode. This is needed to give a SW reset for the phone. Which in turn is needed to get the aligned I/Q values in use. – Go to Product ––> Band ––> GSM – Go to RF controls menu and start transmission on channel 60, power level 10, TX data type 1. – Check the levels of CHF and CHF + 67.71 kHz.
PAMS NSE 8/9 Technical Documentation Service Software Instructions 4. Energy Management Calibration Equipment – Voltage source – within 9–15VDC range. – MJS–13 Module Repair Jig. Procedure – Connect power supply to MJS–13. – Start up WinTesla. – Set switch on MSJ–13 to ( local position)* – Choose Tuning menu and then Energy Management Calibration. – Select no.2 Battery Voltage and no.3 Charger Voltage. – Press Run. – Press OK to save Battery Voltage. – Press OK to save Charger Voltage.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Common User Interface All WinTesla files share a common interface which are detailed in the WinTesla help files once the software is installed. A typical example is shown in the figure below.
PAMS NSE 8/9 Service Software Instructions Technical Documentation NSE–8 Features Product New command Activation Status Bar Text Alt, P, N Rescan a new phone Ctrl+R If phone is changed (with same phone type only serial number is changed) phone will be initialised. If phone is changed to different phone type the current DLLs are unloaded and new ones are loaded for that phone. If the Quick/RF Info view is open, window will be automatically updated.
PAMS NSE 8/9 Service Software Instructions Technical Documentation The After Sales SW sets automatically the MS state to local mode when needed. If phone identification view is open, window will be automatically updated. Also if RF Information Window is open it will be updated to quick info view. Local Mode Activation Status Bar Text Alt, P, L Initialises phone to local mode Shift+F5 Selection will change the MS state to local.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Activate Faultlog Activation Status Bar Text Alt, P, F, A F9 Activates the faultlog. Only enabled when a user has logged in. Edit Faultlog Activation Status Bar Text Alt, P, F, A Allows user to edit faultlog entries. Only enabled when a user has logged in. FastNAM command Activation Status Bar Text Alt, P, N F8 This menu is only enabled when FastNAM functionality is included in Win Tesla.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Tuning The tuning menu offers functions for ME adjustments. RX Calibration... command Activation Status Bar Text Alt, T,R Open RX Calibration dialog box Starts RX calibration. When calibrating the RX it is nessessary to first calibrate in GSM and then in PCN. WinTesla will automatically change to GSM if the calibration is started in PCN.
PAMS NSE 8/9 Technical Documentation Service Software Instructions 5. The RX Calibration dialog will be updated when previous steps are done. Dialog mode: modal RX Calibration dialog has the following items: AFC information box: Shows AFC init value, AFC slope and PSW slope values.
PAMS NSE 8/9 Service Software Instructions Technical Documentation AGC, DAC, Voltage and Difference. The difference column shows the difference between tuned DAC values and mean straight line calculated from part slopes in dBs (see /1/). This can be calculated when all measurement results have been received from phone. Repeat button (ALT+R): The measurement can be started again by pressing this button. Save button (ALT+S): Dialog is closed and tuning is saved to phone.
PAMS NSE 8/9 Technical Documentation Service Software Instructions Then the user is requested to select in the Start Tuning dialog which tuning values to use. If the Start Tuning dialog is not shown the tuning will use the EEPROM values directly. Start Tuning dialog has following items: Start Tuning With list box (ALT+S): Current Values in PC memory Tuning values are load from program’s internal memory. EEPROM Values Tuning values are load from ME’s EEPROM.
PAMS NSE 8/9 Service Software Instructions Technical Documentation The TX Power Tuning dialog will be activated automatically after value selection. Dialog mode: modal TX Power Tuning dialog has following items: Power Level & Coefficients list box (ALT+L): The power is presented in GSM or PCN values. The test value is not saved to the EEPROM. The test value can be changed during tuning as other power coefficients and the program remembers its value when tuning function is activated later again.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Base level calculation check box: If this box is checked the base level is calculated. +/– buttons (+/– and left/right cursor keys): + and – buttons will cause power changing by 0.25dB steps. When these keys are used the coefficient value is updated on the tuning window. Save button (ENTER): Dialog is closed and tuned values are saved to phone. Cancel button (ESC): Dialog is closed and tuning is not saved to phone.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Tx I/Q... command Activation Status Bar Text Alt, T,Q Open TX I/Q Tuning dialog box This function is used for tuning TX I and Q branch DC offset, amplitude difference and phase difference. It is not possible to tune TX I/Q in GSM. WinTesla will automatically change to PCN if the calibration is started in GSM. Then the user is requested to select in the Start Tuning dialog which tuning values to use.
PAMS NSE 8/9 Technical Documentation Service Software Instructions Dialog mode: modal TX I/Q Tuning has following items: Tune TX I DC Offset scroll bar (ALT+I): The DC Offset is shown as percents (%) from the ± maximum value. 0% means that there is no DC. The value range is –100%...100%. The value is rounded to the nearest integer value. Tune TX Q DC Offset scroll bar (ALT+Q): The operation of this function is the same as one above, except with this selection the Q branch DC Offset is tuned.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Energy Management Calibration... command Activation Status Bar Text Alt, T,E Energy Management Calibration This command opens the Energy Management Calibration dialog box: The Energy Management Calibration dialog box contains the following options: Run button (ALT+R): The selected energy management calibrations are performed, Close button (ENTER): The dialog box is closed without performing energy management calibration.
PAMS NSE 8/9 Technical Documentation Service Software Instructions The settings to be selected are: 1. Run battery & charger default values checkbox (ALT+1): Loads battery & charger default values to phone when selected. 2. Battery voltage checkbox (ALT+2): Calibrates battery voltage A/D value. 3. Charger voltage checkbox (ALT+3): Calibrates charge voltage A/D value. The user is asked to connect the correct charging voltage and current limit. 4.
PAMS NSE 8/9 Service Software Instructions Technical Documentation DC/DC Tuning Command Activation Status Bar Text Alt, T,D DC/DC (Vdc_out) tuning This command opens the DC/DC Tuning dialog box. This dialog box allows you to set the DC/DC mode used and to check the different voltage levels for the all power levels when in Auto mode. The tuning is done for the currently selected band (GSM/PCN). The modeless RF Information window is opened.
PAMS NSE 8/9 Technical Documentation Service Software Instructions This is done to save power. In standby, idle and the lower power levels the voltage is low and only when transmitting on the higher power levels, the vibrator is on or the buzzer is on is a high output voltage required. When Auto mode is selected the phone is set to the TX power level highlighted in the listbox. The phone will set the DC/DC output voltage according to the VDC Out value shown.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Testing The Testing sub menu offers functions for ME testing. RF Controls... command Activation Status Bar Text Alt, E,R Open RF Controls dialog box This function is used for RF testing. Command opens RF Controls dialog, which contains data for testing and adjustments.
PAMS NSE 8/9 Technical Documentation Service Software Instructions RF Information window is updated The RX value is always given as default. Note! Function is activated immediately, Apply is not needed. TX radio button (ALT+T): When TX is selected, the next functions are made: Data transmission is activated If operation mode is continuous, – Operation mode is set to burst RF Information window is updated Continuous mode radio button is disabled.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Burst radio button (ALT+B): When burst selection is used, synthesiser is controlled by using receiving/transmission/measuring synthesiser control sequence synthesiser channel numbers are as given with Channel/Monitoring Channel selections if Active Unit is TX, data (selected with TX Data Type) is sent and the TX power is connected Note! Function is activated immediately, Apply is not needed.
PAMS NSE 8/9 Technical Documentation Service Software Instructions AGC edit box (ALT+G): This selection allows user to edit the AGC dBvalue. The AGC value is shown only when its value is controlled by PC. When Active Unit has value RX and Operation Mode is continuous, AGC is controlled by PC except when next adjustment functions are activated: RSSI Calibration AFC Diagram Apply button (ALT+A): Accepts entered values and validates them.
PAMS NSE 8/9 Service Software Instructions Technical Documentation OPERATION MODE = BURST: AGC values: Greyed Continuous Mode Channel: Greyed Channel: Updated Monitoring Channel: Updated OPERATION MODE = CONT: AGC values: Updated Continuous Mode Channel: Updated Channel: Greyed Monitoring Channel: Greyed RSSI Reading...
PAMS NSE 8/9 Service Software Instructions Technical Documentation Self Tests... command Activation Status Bar Text Alt, E,S Open MCU Self–tests dialog box Command is used for reading self test results and running self tests. When the selection is made, the test result is read from ME. The test result will be shown to the user within MCU Self–test dialog.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Not valid RUNNING.... Note that power–off test have no values, because if test has been passed, power has been turned off. If power–off test fails a special error message window is shown. If no response is received to power off test message in a few seconds, the user is informed by special info window, where user is asked to turn the power on and then press the return key.
PAMS NSE 8/9 Service Software Instructions Technical Documentation B Security Data................... C EEPROM Tune Checksum............ D PPM Checksum.................... E MCU Download DSP................ F DSP Alive....................... G COBBA Serial....................... H COBBA Parallel..................... I EEPROM Sec Checksum................ J PPM Validity.................................. K Warranty State.............................. ADC Readings...
PAMS NSE 8/9 Service Software Instructions Technical Documentation Battery Voltage.........: Battery Temperature.....: Charge Voltage..........: Charge Current..........: PSCC Voltage............: Acessory Detection......: VDC Out...................: VCXO Temperature........: Hook Informaton........: Audio... command Activation Status Bar Text Alt, E,U Opens a submenu which contains following options: Internal Audio Loops Activation Status Bar Text Alt, E,U,I Open Internal Audio loops dialog box.
PAMS NSE 8/9 Technical Documentation Service Software Instructions Dialog mode: modal Internal Audio Loops dialog has following items: Buzzer group: Next three different values can be selected for Buzzer: Volume On radio button (ALT+V): Turns buzzer on. Volume Off radio button (ALT+O): Turns buzzer off. Level drop down list (ALT+L): Sets level of a buzzer. Allowed range 0...
PAMS NSE 8/9 Service Software Instructions Technical Documentation Loop group: Next two different values can be selected for loop: Off radio button (ALT+F): Turns audio loop off. On radio button (ALT+N): Turns audio loop on. When the dialog is closed, the Buzzer Volume is always switched off. Also internal audio loop is turned off. User Interface... command Activation Status Bar Text Alt, E,T Open User Interface Tests dialog box Command is used for making display tests in Display Tests dialog.
PAMS NSE 8/9 Technical Documentation Service Software Instructions Dialog mode: modal Call Simulation dialog has following items: TX Power Level edit box (ALT+T): All power levels can be selected. This updates same parameter as TX Power Level in the RF Controls dialog. Note that TEST value cannot be selected. If TEST value was in use when Call simulation menu selected, power level is changed to smallest value. Channel edit box (ALT+C): This tells the normal operating RF channel number.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Get Defaults button (ALT+G): Gets default Call Simulation values as current values. Noise Sensitivity... command Activation Status Bar Text Alt, E,N Opens Noise sensitivity dialog box Command is used for noise sensitivity measurement.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Clipping distance is the difference to the signal clipping value. SNR is measured in AD converter. The last value on the display is signal power difference between I and Q branch. The numbers are shown in 0.1dB accuracy. The error messages, ”OUT OF RANGE”, are shown only if the SNR and/or amplitude difference values are not acceptable.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Software Product Profile... command Activation Status Bar Text Alt, S,P Open Product Profile settings dialog box. Function is used for making product profile settings. When command is activated the product profile information is read from EEPROM and Product Profile dialog is opened. Dialog mode: modal Product Profile dialog has following items: Settings list box (ALT+E): A list where user can select desired setting.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Options drop list (ALT+O): List allows user to set options to each settings which are listed in Settings list box. Save(OK) button (ENTER) Selections are accepted and saved to EEPROM. Cancel button (ESC) Selections are ignored and control is returned back to main menu. Start Up Self–tests... command Activation Status Bar Text Alt, S,S Open MCU start Up self–tests dialog box.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Selectable Start–Up self tests: 1. PPM Validity 3. A/D Converter Set Factory Values... command Activation Status Bar Text Alt, S,V Set factory values Application does not ask confirmation. Next kind of text will be shown to user: “Setting UI and SCM Factory values...” Dialog mode: modal Default Factory Values dialog has following items: Settings list box: Contains the selectable factory values.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Phone Identity... command Activation Status Bar Text Alt, S,I Open Phone Identity dialog box for editing Function is used to edit phone identity.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Phone Identity dialog has following items: User Name edit box (ALT+U): Field where user can enter user identification. IMEI edit box (ALT+I): Field where user can enter IMEI value. Field can contain up to 40 digits. This field is automatically filled, if ME is connected to the PC when dialog is loaded. Product Code edit box (ALT+P): Field where user can enter Product Code value.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Help button Opens a help text. Write button (ALT+W): Writes programming data to phone. Actions are selected with Action Selection radio button. Read button (ALT+R): Reads identification data from phone and shows it in dialog controls. Needed data is selected by Action Selection radio button. Save File... button (ALT+S): Writes a file containing data needed by security place application to create needed programming data.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Production Data Edit... command Activation Status Bar Text Alt, S,P Open Production Data Edit dialog box This command is used for programming HW version to phone. Function opens the following Production Data Edit dialog box. Dialog mode: modal Production Data dialog has the following items: Production Code edit box (read only): Displays production code. Order Number edit box (read only): Displays order number. Production Ser.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Dealer The dealer sub menu offers functions for ME settings for dealers. User Settings... command Activation Status Bar Text Alt, D,U Open User Setting dialog box This command is used to edit user settings. Dialog mode: modal User Settings dialog box has following items: Save File... button (ALT+S): User can save user settings to file. Load File button (ALT+L): User can load user settings from file. Edit...
PAMS NSE 8/9 Service Software Instructions Technical Documentation Cancel button (ESC): Closes the dialog box Short Code Memory... command Activation Status Bar Text The NSE–8 phone does not contain a ME short code memory and the MS selection is disabled. Only the SIM SCM can be used and if no SIM card is present in the phone the SCM dialog will not open. Dialog mode: modal Edit SCM dialog has the following items: Loc static text: Display current location. Name edit box (ALT+A): Edit the Name.
PAMS NSE 8/9 Service Software Instructions Technical Documentation List for available names and numbers. Write button (ALT+W): Write SCM values to phone and checks the validity of names and numbers. Read button (ALT+R): Read SCM values from phone. Save File... button (ALT+S): Opens a default Windows File Save As dialog and asks filename where to save SCM values. Load File... button (ALT+L): Opens a default Windows File Open dialog and asks filename where from load SCM values.
PAMS NSE 8/9 Service Software Instructions Technical Documentation When data is written or read phone waiting dialog is showed to user. Dialog mode: modal SCM & User Settings dialog box has following items: File Name edit field (ALT+F): User can edit file name or select file with Open File dialog. When dialog is opened, it contains name of the previously saved or loaded file. Write Phone button (ALT+W): Loads settings from file and writes them to phone.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Restore User Defaults... command Activation Status Bar Text Alt, D,R Restore user default settings: Reading from ME.... Command is used to restore the user settings of the MS All settings specified in the selected market area and with setting files present are enabled and can be selected. The files to be used are defined for each market area in the ini–file wintesla\nse–8\nse–8.ini.
PAMS NSE 8/9 Service Software Instructions Technical Documentation //VasFile= GMSFile=NSE8EURO.GMS CLI Logos and VAS Settings are not supported by the NSE–8 and NSE–9 phones and must not be specified. Set UI/DEV Default Values... command Activation Status Bar Text Alt, D,V Reset phone to UI and SCM factory settings After selection application asks confirmation: “Are you sure you want to set UI to factory settings?”. If Yes is answered, default settings are resetted to phone.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Flash PPM... command Activation Status Bar Text Alt, D,P Open Post–programmable Memory dialog box. This command is used to load PPM from file to phone. Application checks version numbers of PPM package and ME, when file is loaded.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Operator Settings.......command Activation Status Bar Text Alt, DO Operator settings: Reading from ME..... Command is used to set the operator settings to the MS IWR Swap data ......command Activation Status Bar Text Alt, D, I Command is used to swap IWR data.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Flash Phone... command Activation Status Bar Text Alt, S,F This command is used for flashing new software into the phone. Function opens the following Flash Phone dialog box. When flashing is started, a window will show status and progress. Flashing the phone supports both the FPS4 flash prommer setup and the FLS–X device. The device used is selected in the menu Configure | FLS–1.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Example: [EURO_A] // flash files 1.priority Rom4ImageFile=nse8nx03.000 Rom4PpmFile=nse8nx03.00a If the image file entry is missing in the market area section then the common reference is searched for: [NSE–8_RESTOREFILES] // image file 2.priority Rom4ImageFile= nse8nx03.000 The flash files can also be selected directly using the .... buttons. Flash button: Starts flashing. Close button: Closes the flash dialog. View Quick/RF Info...
PAMS NSE 8/9 Service Software Instructions Technical Documentation Phone Identity... command Activation Status Bar Text Alt, V,P View Phone Identity. Command opens Phone Identity Information dialog, which shows identification information. Information is shown in a modeless dialog which may be left open during other operations. It is also updated when ever needed.
PAMS NSE 8/9 Service Software Instructions Technical Documentation Appendix 1, Vocabulary Page 68 Abreviation Description ASIC Custom circuit which for instance controls communication between MCU and DSP BBD–3 Service battery CLF Common Look and Feel CLI Calling Line Identification COBBA Common Base Band Analog DATA DATA interface module DAU–9S/P MBUS/FBUS cable DLL Dynamic Link Library DSP Digital Signal Processor which controls radio interface and speech coding/decoding EEPROM Me
PAMS NSE 8/9 Service Software Instructions Technical Documentation PKD–1/1NS/1CS Hardware protection key (DESKEY DK2) for protecting service software from illegal copying.
PAMS NSE 8/9 Service Software Instructions Technical Documentation [This page intentionally left blank] Page 70 Issue 1 07/99