User Guide
CC Technical Documentation Troubleshooting - RF (Part 2)
RM-11
Issue 1 02/2004 ©2004 Nokia Corporation Confidential Page 5
Check for the presence of the signal at the following points (use a high-impedance
RF probe):
• CLK19M2_B, clock reference to Batman, should be +4.5dBm
• CLK19M2_R, clock reference to Robin, should be +4.5dBm
• CLK19M2_UPP, clock reference to UPP, should be +7.5dBm
Figure 4: Presence of signal test points
If you do not see the VCTCXO signal at any of these points, check the voltages at the
following supply lines:
• VR3, main supply line for VCTCXO circuitry, should be 2.78VDC
• VIO, supply line for buffer amplifier, should be 1.8VDC
VR3 = 2.78VDC
VIO = 1.8VDC
To Batman PLL
19.2 MHz @ +4.5 dBm
(CLK19M2_B)
VCTCXO
To Robin PLL
19.2 MHz @ +4.5 dBm
(CLK19M2_R)
To Baseband UPP
19.2 MHz @ +7.5 dBm
(CLK19M2_UPP)