Use the PDM settings from the previous section. Following are the approximate power
levels you should expect for the PCS band (Channel 600):
C660 Output of Robin (N601), input to Hornet (N602)
Probed power -2dBm (If not, then replace Robin)
C627 Output of split-band filter (Z601)
(Gain 10.5dB – (filter loss 2.3dB) 8.2dB)
Probed power 7dBm (If not, then replace Hornet)
C802 Output of the TX Switch (Loss 1dB)
Probed power +6dBm (If not, then replace the switch)
C803 Output of PCS PA (use 10dB pad on probe or just sniff part)
Probed power +18dBm (If not, then replace the PCS PA)
C809 IREF into PCS PA should be 2.7V (If not, trace back to Robin and then
to the BB)
Cell and AMPS Band TX Probe Points
Figure 20: Cell and AMPS band TX probe points