User Guide
RM-11
Troubleshooting - RF (Part 2) CC Technical Documentation
Page 16 ©2004 Nokia Corporation Confidential Issue 1 02/2004
Use the PDM settings from the previous section. Following are the approximate power
levels you should expect for the PCS band (Channel 600):
• C660 Output of Robin (N601), input to Hornet (N602)
Probed power ≅-2dBm (If not, then replace Robin)
• C627 Output of split-band filter (Z601)
(Gain ≅10.5dB – (filter loss 2.3dB) ≅ 8.2dB)
Probed power ≅ 7dBm (If not, then replace Hornet)
• C802 Output of the TX Switch (Loss ≅ 1dB)
Probed power ≅ +6dBm (If not, then replace the switch)
• C803 Output of PCS PA (use 10dB pad on probe or just sniff part)
Probed power ≅ +18dBm (If not, then replace the PCS PA)
• C809 IREF into PCS PA should be ≅ 2.7V (If not, trace back to Robin and then
to the BB)
Cell and AMPS Band TX Probe Points
Figure 20: Cell and AMPS band TX probe points
1