TX VHF Layout
Figure 11: TX VHF Layout
Incorrect TX VHF Frequency
Possible causes:
Power supplies to PLL portion of Robin IC (N601) missing or low (VR3)
Loop filter or resonator components missing or incorrectly installed
19.2MHz reference clock missing or low
Programming is incorrect
Component failure (PLL IC)
RF Probing Point:
Cell: 346.2 MHz @ -6.5 dBm
PCS: 416.2 MHz @-6.5 dBm
Lock Voltage Probing Point:
DC voltage between 1V and 2V
Robin IC with integrated PLL