The RM-11 baseband is powered from five different UEM regulators:
Table 2 includes the UEM voltage regulators used by the RF.
A charge pump used by VR1A is constructed around the UEM. The charge pump works
with Cbus (1.2 MHz Clk) and gives a 4.75 V regulated output voltage to the RF.
Clock Distribution
RFClk (19.2 MHz Analog)
The baseband’s main clock signal is generated from the VCTCXO (G503). This 19.2 MHz
clock signal is generated at the RF and fed to the UPP’s RFCLK pin.
Table 1: RM-11 Baseband Regulators
Regulator
Maximum
current (mA)
Vout (V) Notes
VCORE
DD/DC
300 1.5 Output voltage selectable 1.0V/1.3V/1.5V/1.8V
Default power at power-up is 1.5V
VIO 150 1.8 Enabled always except during power-off mode
VFLASH1 70 2.78 Enabled always except during power-off mode
VFLASH2 40 2.78 Enabled only when data cable is connected
VANA 80 2.78 Enabled only when the system is awake (off during sleep
and power-off modes)
VSIM 25 3.0 Not used
Table 2: RM-11 RF Regulators
Regulator
Maximum
current (mA)
Vout (V) Notes
VR1A 10 4.75 Enabled when the receiver is on
VR1B 10 4.75 Enabled when the transmitter is on
VR2 100 2.78 Enabled when the transmitter is on
VR3 20 2.78 Enabled when SleepX is high
VR4 50 2.78 Enabled when the receiver is on
VR5 50 2.78 Enabled when the receiver is on
VR6 50 2.78 Enabled when the transmitter is on
VR7 45 2.78 Enabled when the receiver is on