User Guide
RH-30/RH-31 Company Confidential
System Module Nokia Customer Care
Page 42 © 2004 Nokia Corporation. Issue 2 11/2004
DC characteristics
Regulators
The transceiver baseband section has a multi function analog ASIC, UEM, which contains
among other functions six pieces of 2.78 V linear regulators and a 4.8 V switching regu-
lator. All the regulators can be controlled individually by the 2.78 V logic directly or
through a control register. Normally, direct control is needed because of switching speed
requirement: the regulators are used to enable the RF-functions which means that the
controls must be fast enough.
The use of the regulators can be seen in the power distribution diagram which is pre-
sented in Figure 20, “Power distribution diagram,” on page 44.
The seven regulators are named VR1 to VR7. VrefRF01 and VrefRF02 are used as the ref-
erence voltages for the Helgo, VrefRF01 (1.35V) for the bias reference and VrefRF02
(1.35V) for the RX ADC (analog-to-digital converter) reference.
The regulators (except for VR7) are connected to the Helgo. Different modes of operation
can be selected inside the Helgo according to the control information coming through
the RFBus.
List of the needed supply voltages
Volt. source Load
VR1 PLL charge pump (4.8 V)
VR2 TX modulators, VPECTRL3s (ALC), driver
VR3 VCTCXO, synthesizer digital parts
VR4 Helgo pre-amps, mixers, DtoS
VR5 dividers, LO-buffers, prescaler
VR6 LNAs, Helgo baseband (Vdd_bb)
VR7 VCO
VrefRF01 ref. voltage for Helgo
VrefRF02 ref. voltage for Helgo
Vbatt PA