User Guide
Nokia Customer Care System Module
Company Confidential RH-30/RH-31
Issue 2 11/2004 © 2004 Nokia Corporation. Page 39
Backup battery
Backup battery is used in case when main battery is either removed or discharged.
Backup battery is used for keeping real-time clock running for minimum of 30 minutes.
Rechargeable backup battery is connected between UEM VBACK and GND. In UEM
backup battery charging high limit is set to 3.2V. The cut–off limit voltage (V BUCoff–)
for backup battery is 2.0V. Backup battery charging is controlled by MCU by writing into
UEM register.
Li-Ion SMD battery type is used. The nominal capacity of the battery is 0.01 mAh.
Table 2: Backup Battery circuitry
Parameter
Test conditions
Symbol Min Typ Max Units
Back-up battery voltage VBACK 2.43 3.3 V
Back-up battery cut-off limit V_BU
COFF+
V_BU
COFF-
2.04
1.94
2.10
2.0
2.16
2.06
V
V
Charging voltage (VBAT ≥ 3.4V)
VBU 3.1 3.2 3.3 V
Charging current I
LIMVBU
150 500 mA