User Guide

RH-30/RH-31 Company Confidential
System Module Nokia Customer Care
Page 28 © 2004 Nokia Corporation. Issue 2 11/2004
Power up with PWR key
When the Power on key is pressed the UEM enters the power up sequence as described in
the previous paragraph. Pressing the power key causes the PWRONX pin on the UEM to
be grounded. The UEM PWRONX signal is not part of the keypad matrix. The power key is
only connected to the UEM. This means that when pressing the power key an interrupt is
generated to the UPP that starts the MCU.
The MCU then reads the UEM interrupt register and notice that it is a PWRONX interrupt.
The MCU now reads the status of the PWRONX signal using the UEM control bus, CBUS.
If the PWRONX signal stays low for a certain time the MCU accepts this as a valid power
on state and continues with the SW initialization of the baseband. If the power on key
does not indicate a valid power on situation, the MCU powers off the baseband.
Power up when charger is connected
In order to be able to detect and start charging in a case where the main battery is fully
discharged (empty) and hence UEM has no supply (NO_SUPPLY or BACKUP mode of
UEM) charging is controlled by START-UP CHARGING circuitry.
Whenever VBAT level is detected to be below master reset threshold (VMSTR-) charging
is controlled by START_UP charge circuitry. Connecting a charger forces VCHAR input to
rise above charger detection threshold, VCHDET+.
By detection start-up charging is started. UEM generates 100mA constant output cur-
rent from the connected charger’s output voltage. As battery charges its voltage rises,
and when VBAT voltage level higher than master reset threshold limit (VMSTR+) is
detected START_UP charge is terminated.
Monitoring the VBAT voltage level is done by charge control block (CHACON). MSTRX=‘1’
output reset signal (internal to UEM) is given to UEM’s RESET block when VBAT>VMSTR+
and UEM enters into reset sequence described in section Power Up and Reset.
If VBAT is detected to fall below VMSTR- during start-up charging, charging is cancelled.
It will restart if new rising edge on VCHAR input is detected (VCHAR rising above VCH-
DET+).
Power up when battery is connected
Baseband can be powered up by connecting battery with sufficient voltage. Battery volt-
age has to be over UEM internal comparator threshold level, Vcoff+. Battery low limit is
specified in Table 2. Battery Voltage Range. When battery voltage is detected, UEM
enters to reset sequence as described in section Power Up and Reset
Phone can be powered up to LOCAL mode by setting BSI resistor 560. This causes MCU
to wake up directly when battery voltage is supplied.