Customer Care Solutions DTX-3 Series Transceivers Service Tools Issue 1 4/03 Nokia Corporation
DTX-3 Service Tools CCS Technical Documentation Table of Contents Page No Flash Loading Adapter FLA-7 .....................................................................................3 Flash Prommer FPS-4 (Sales Pack) .............................................................................4 Security Box TDF-4 ....................................................................................................5 DC Power Cable SCF-7 ..................................................................
DTX-3 Service Tools CCS Technical Documentation Flash Loading Adapter FLA-7 The flash loading adapter FLA-7 is used in MCU SW upgrade. Service cable DKT-6A is also needed. Power is supplied to FLA-7 from ACH-6E charger. Power for the FPS-4 can be connected via FLA-7 by SCF-7 DC power cable. The adapter is connected to the flash prommer FPS-4 by the AXS-5 cable and to the security box TDF-4 by the XCM-1 cable.
DTX-3 Service Tools CCS Technical Documentation Flash Prommer FPS-4 (Sales Pack) The flash prommer FPS-4 is used to update the main software of the phone. Updating is done by first loading the new MCU software from the PC to the flash prommer, and then loading the new SW from the prommer to the phone. When updating more than one phone in succession, the MCU soft ware only needs to be loaded to the prommer once.
DTX-3 Service Tools CCS Technical Documentation Security Box TDF-4 The security box TDF-4 is required for updating MCU software, and infra red testing. Note: TDF-4 is delivered in de-activated mode. Fill in the enclosed Activation Request Form, and fax to NMP Salo to get the activation code.
DTX-3 Service Tools CCS Technical Documentation DC Power Cable SCF-7 The DC power cable SCF-7 is used for connecting power from ACL-3 charger via FLA-7 to FPS-4.
DTX-3 Service Tools CCS Technical Documentation D9-D9 Cable AXS-4 The D9-D9 cable AXS-4 is used to connect two 9-pin D-connectors, for example, between PC and TDF-4 security box. The D9-D9 cable AXS-4 is used to connect TDF-4 security box to FPS-4 Flash Prommer.
DTX-3 Service Tools CCS Technical Documentation D15-D15 Cable AXS-5 The D15-D15 cable AXS-5 is used to connect two 15-pin D-connectors, for example, between FLA-7 and FPS-4.
DTX-3 Service Tools CCS Technical Documentation Service Cable DKT-6A Service Cable DKT-6A is used to connect FLA-7 to DTX-3. One connector a 6-pin modular connector, the other is a 10-pin modular connector.
DTX-3 Service Tools CCS Technical Documentation Line Adapter Test cable SCS-24 Line Adapter Test Cable SCS-24 is connected between trunk connector and T-adapter when testing the Nokia 32 Application Module.
DTX-3 Service Tools CCS Technical Documentation SW Security Device PKD-1 SW security device is a piece of hardware enabling the use of the service software when connected to the parallel (LPT) port of the PC. Without the dongle present it is not possible to use the service software. Printer or any such device can be connected to the PC through the dongle if needed.
DTX-3 Service Tools CCS Technical Documentation Power Cable PCC-1B Power Cable PCC-1B is used to connect the DTX-3 application module with the Flash Loading Adapter.
DTX-3 Service Tools CCS Technical Documentation Modular T-Adapter Modular T-Adapter is used in testing the Nokia 32 Application module. SCS-24 Line Adapter Test Cable from trunk Connector and CA-15DS Line Adapter test cable from extension connector are connected to the T-Adapter during loop test. DKT-7A MBUS Cable is also connected to the T-connector to make the connection to PC.
DTX-3 Service Tools CCS Technical Documentation MBUS Cable DKT-7A Service MBUS cable connects the PC to the T-Adapter when testing the Nokia 32 Application Module.
DTX-3 Service Tools CCS Technical Documentation Line Adapter Test Cable CA-15DS Line adapter test cable CA-15DS is connected between extension and T-connector (4626134) when testing the Nokia 32. It consists of 50cm of flat 6-core cable with 6-pin modular connector at each end.
DTX-3 Service Tools CCS Technical Documentation [This page intentionally left blank.