User Interface Features
Three light indicators (LEDs) form the user interface of the TME-3.
LED 1 shows the terminal status, while the other two are reserved for the application
module following start-up.
During start-up and special operations, all three light indicators are in terminal use. The
functionality of the light indicators in start-up, normal, and special situations is
described below.
All three LEDs can also be configured so that they will not show any status and will
remain off during any operation.
Figure 3: UIF LEDs
Start-up Operation
Table 1: Start-up Operation:
LED 1 LED 2 Status LED Description
- - - Power off / silent mode
Green scan Green scan Green scan Power on, connecting to network
- Red blink - PIN query / new PIN query
- Red blink Red blink PUK query
Intensity of Field Strength:
Red blink - - Non-acceptable <-105 dBm
Green Blink - - -105 … -100 dBm
Green - - Weak -100 … -95 dBm
Green Green Blink - -95 … -90 dBm
Green Green - Moderate -90 … -85 dBm
Green Green Green Blink -85 … -80 dBm
Green Green Green Good >-80 dBm