User Guide

TME-3
Tuning, Flashing and Final Testing Instructions PAMS Technical Documentation
Page 14 Nokia Corporation. Issue 3 10/03
RX calibration,step3: RX AM suppression
Measuring equipment: RF generator (AM modulation)
Maintenance => Tuning => Rx Am suppression
Figure 9: RX AM Suppression window
Start => PM settings => OK, set generator frequency and level as ordered
Press "Tune" (Only Automatic mode available on AMS version of Phoenix)
One "I" and "Q" line values must be 0, other values 0...31
Caution: 50kHz modulating frequency too much for some RF generators =>
>15kHz can be used instead
RSSI level should be around -107dBm