PAMS Technical Documentation Tuning, Flashing and Final Testing Instruc-
TME-3
Issue 3 10/03 Nokia Corporation. Page 13
RX calibration, step2
Measuring equipment: RF generator
Maintenance => Tuning => Rx calibration
Figure 8: RX calibration window
• Caution: Check toolbar "Autom. XX dB" that XX is 60!!
• Press "Start" (Only Automatic mode available on AMS version of Phoenix)
• Select Start parameter: PM settings => OK
• Press "Calibrate" and set generator frequency and level as ordered => OK
• Must be done separately on both bands
• RSSI0…RSSI8 values should be ascending and about 70…150 (EGSM) and
65…150 (DCS1800)
• When tuning EGSM synthesizer AFC tuning is also performed