User Guide
PAMS Technical Documentation Disassembly and Troubleshooting
TME-3
Issue 3 10/03 Nokia Corporation. Page 41
7, 8, 9 mC resets the WATCHDOG (
Twr < Toff
)
10. mC switches Power Off by letting watchdog elapse, (
Twr > Toff
). PURX low, regula-
tors disabled.
11. Power switched on via
power switch
(low level),
VBATT > V
COFF+
:
DELAY1 starts.
12. DELAY1 elapsed:, Enable regulator reference buffers, time delay DELAY2 starts
13. DELAY2 elapses: Enable VFLASH1 regulator. DELAY3 starts.
14. DELAY3 elapses: ENABLE VIO, VCORE, VANA and VR3 regulators. DELAY4 starts.
15. DELAY4 elapses: Release PURX. UEM in ACTIVE mode. RF regulators can be
enabled through register writing.
16,17. VBAT drops below reset level for a
short period (<5
m
s)
. Stay in ACTIVE.
18. VBAT drops below V
COFF-
when battery discharges =>PURX low, disable regulators
=>PWR_OFF
19. VBAT drops below V
MSTR-
=> NO_SUPPLY or BACK_UP mode
Flash 1 signal
Figure 38: Flash 1 signal
CH1 = BSI
CH2 = MBUS
CH3 = FBUSTX
CH4 = FBUSRX
Measure points
Production test pattern
(J396)
FLASH_1