User Guide

PAMS Technical Documentation Disassembly and Troubleshooting
TME-3
Issue 3 10/03 Nokia Corporation. Page 25
Synthesizer
General instructions for synthesizer troubleshooting
Connect test jig to the PC with DAU-9S cable or to FPS-8 Flash Prommer with XCS-4
modular cable.
Make sure that you have PKD-1 dongle connected to the PCs parallel port.
Connect DC power supply or FPS-8 to module test jig with a suitable cable.
Set the DC supply voltage to 13.5 V.
Set the phone module to test jig and start Phoenix service software
Initialize connection to phone. (use FBUS driver when using DAU9S and COMBOX driver
when using FPS-8)
Select product from the menu
File -> Choose product -> TME-3
From toolbar set operating mode to "Local"
Activate RF controls window from the menu
Maintenance -> Testing -> RF Controls
From the RF controls window
- Select band "GSM900" or "GSM 1800" (Default = "GSM900")
- Set Active unit to "Rx" (Default = "Rx")
- Set Operation mode to "Continuous" (Default = "Burst")
- Set Rx/Tx channel to 37 on GSM900 band or 700 on GSM1800 band (Defaults)
For synthesizer schematic refer to the A3 size schematics in the back of the manual