User Guide
RH-53/54
Nokia Customer Care
30 COMPANY CONFIDENTIAL ISSUE 1 09/2004
Copyright © 2004 Nokia. All Rights Reserved.
The names to the left are the signal names used on the RF schematics
Table 3: Supply names
See the picture below for measuring points at the UEM (D200).
Figure 19: UEM measuring points
There is only one PLL synthesizer generating Local Oscillator frequencies for both RX and TX
in both bands (Lowband and Highband). The VCO frequency is divided by 2 for Highband op-
eration or by 4 for Lowband operation inside the Mjoelner IC.
Supply
name RF
Supply
name UEM
Min Typ Max Unit
VCP VR1A 4.54 4.75 4.9 V
VTX VR2 2.64 2.78 2.86 V
VXO VR3 2.64 2.78 2.86 V
VPLL VR5 2.64 2.78 2.86 V
VRX VR6 2.64 2.78 2.86 V
VVCO VR7 2.64 2.78 2.86 V
VBB VIO 1.72 1.8 1.88 V
VREF2 VrefRF01 1.334 1.35 1.366 V
VBATT BATTERY 3.1 3.6 5.2 V
VR6=VRX (C225) VR1A=VCP (C221)
VR7=VVCO (C224)
VR2=VTX (C223)
VR3=VXO (C227)
VrefRF01=VREF1 (C231)
VR5=VPLL (C226)
VIO=VBB (C218)