User Guide

NHB–3
Technical Documentation
PAMS
Tuning Instructions
Original 26/97
9
Tuning Steps
1. AFC Diagram Storage
This tuning is used to calibrate the automatic frequency control range.
AFC tuning:
Reference value for the received signal strength meter are program tuned.
RSSI reference signal level programming:
Select Main menu option 7, ”Phone mode” to change phone mode to local if
it is not done already.
Check that ” Cont mode channel” is 661.
Select: option 3 ”Testing and adjustment” and option 2 ”Adjustment”.
Set RF generator frequency 1960.06771 MHz at level –45 dBm + RF cable
and RF antenna adapter attenuation.
Select adjustments menu option ”AFC Diagram” and press <Enter>
The measurement result should be;
Low –26...–14 kHz
Middle ±3.0 kHz (depends on generator frequency accuracy)
High 14...26 kHz
Press <Esc> key and store values to EEPROM with <Y> key.