3. I/Q Modulator Amplitude Balance and Phase Shift Tuning
The purpose of this tunig operation is to adjust the I/Q modulator d.c. offsets
and the I/Q modulator amplitude balance and phase shift.
I/Q modulator d.c. offsets, amplitude balance and phase shift tuning:
Connect spectrum analyzer (with attenuator if needed) to phone antenna
connector.
Select adjustment menu option ”TX I/Q Tuning” and press <Enter>.
Check that TX power level is level 5, Cont. mode channel is 661 and TX
data type is 1.
Adjust spectrum analyzer centre frequency to 1880 MHz, Ref level to
30 dBm and Span 200 kHz (500 kHz can be used to see both sides of the
spectre)
Set also Res BW to 10 kHz, Video BW 1 kHz and Sweep time 1.0 s.
Set triggering to Free Run
–67.71 kHz +67.71 kHz
CHF
> 30 dB
> 35 dB
Set this value
to minimum
Amplitude &
phase difference:
Set this value
to minimum
D.C. offset
tunings:
Select option ”TX I DC offset”.
Adjust the level of centre frequency (CHF signal) to minimum by varying D/A
converter value with <+> and <–> keys (or occasionally cursor left and right
keys).
The amplitude difference between CHF–67.7 kHz and CHF should be
>30 dB (See picture).
When value is OK move to the next option with cursor keys.
Select option ”TX Q DC offset”.