User Guide

NHB–3
Technical Documentation
PAMS
Tuning Instructions
Original 26/97
10
2. RSSI Reference Signal Level Storage
Start the service software and go to ”Main” menu.
Initialize phone by pressing <2> in the PC keyboard or by choosing
”initialize” with cursor keys and by pressing <ENTER> to confirm the
selection.
Select ”Phone mode” and select local mode with <Enter> key or by pressing
simply the <7> key.
Select ”Testing and Adjustments” menu and press <Enter>.
Select ”Adjustments” menu and press <Enter>.
Select option 1, ”Continuous channel mode”.
–change channel mode to 661
–press <ESC>
Connect RF generator to antenna connector at 1960.06771 MHz
(Channel 661).
Adjust signal generator level to –75 dBm + RF cable and RF antenna adapt-
er attenuation (for example with 2.5 dB attenuation the level is –72.5 dBm).
Select ”RSSI Calibration” and press <Enter>.
Press <Enter> key from PC keyboard to measure the signal strength.
Adjust generator signal amplitude level to –45 dBm + RF cable and RF
antenna adapter attenuation.
Press <Enter> to measure the signal strength.
DAC values should vary from 12 to 25 units between each step.
Press <Esc> key.
Store the value to the EEPROM with <Y> key.