3.2.7 – Charge Voltage Adjustment
This function needs 6 V charge voltage from external power supply. When the
function is activated the next window will be shown.
The A/D converter has positive 10 bit value.
The A/D converter value is read again when previous value is received and
shown on the screen.
If none measurement result is received when <Esc> key is used, the informa-
tion message is shown. The user can remove the information message with
<Y>, <N> or <Esc> key. The measurement will be broken by using <Y> key.
The measurement will continue if <N> or <Esc> key is used. Any other key
doesn’t cause any effect.
When exiting the function the user must answer to the question of saving the
values to EEPROM by using the logic described in a next table:
Key Response
Y The A/D converter
N The tuning is ended without EEPROM writing but the
tuned adjusted AGC values are used when RF controls
are used
Esc The adjustment is continued
other key