User Guide
PAMS
Technical Documentation
NHB–3
Service Software Instructions
Original 26/97
Page 20
The next table shows the information window display on different situations:
Active Unit = TX Operation mode = BURST Not operate continous mo
TX Power Level:
TX Data Type:
Continuos Mode Channel:
Channel:
Monitoring Channel:
AGC:
AFC:
Updated
Updated
Removed
Updated
Removed
Removed
Removed
Active Unit = RX Operation mode = BURST Operation mode = CONT.
TX Power Level:
TX Data Type:
Continuos Mode Channel:
Channel:
Monitoring Channel:
AGC:
AFC:
OFF
Removed
Removed
Updated
Updated
Removed
Removed
OFF
Removed
Updated
Removed
Removed
Updated
Updated
3.1.1 – Active Unit
Either receiving or transmission tests can be selected. When TX is selected,
the following functions will be performed:
– Data type is activated
– Operation mode is burst
– TX power is activated
– TX channel is activated
– Information window is updated
– Monitoring channel is updated
When RX is selected, the next funtions are made:
– Data transmission is deactivated
– TX power is deactivated
– If operation mode is continuous,
– AGC is controlled
– AFC is controlled
– Continuous mode RX channel is activated
– If operation mode is burst,
– RX and monitoring channel are activated
– Information window is updated
3.1.2 – TX Power Level
With this function it’s possible to change the transmission power. The user can
select the needed PCS power value (0...15) by pressing arrow up / down keys
and ENTER. Power value is stored to EEPROM. The test value or base level
selection is made by writing ”T” or ”B” with small or capital letters.