User Guide

TUNING INSTRUCTIONS
9618ARo
6–3–3
NHC–4
Technical Documentation
Copyright Nokia Mobile Phones
Required Equipment
PC/AT computer with the Service software; see Sect. 5 for intructions on
installation and use.
M2BUS adapter DAU–2 and other service accessories; see equipment set-
up pictures.
Audio analyzer
Spectrum analyzer
RF power meter, power measurement sensitivity –10 dBm.
Modulation analyzer with precise frequency measurement.
RF generator
Device to provide specified testmodulation to modulate RF generator.
DMR tester
Multimeter or DVM.
Attenuator and branching unit.
Power supply 1, nom. voltage 12 V.
Power supply 2, nom. voltage 6 V. This is needed only in that case, if you
want to connect the dummy battery direct to the to power supply.
Accuracy of the Equipment During Measurement
Power supply 1; nominal voltage 12 ±0.5 V current cap. min. 1.5 A for ser-
vice box (JBS–7). If you test or tune also the RF booster BSH–4, you need
power supply, which has 5 A output capacity.
Power supply 2 ;nominal voltage 6.0 ±0.1 V, current cap. min. 1.5 A.
Mod. analyzer power level resolution 0.1 dB, accuracy ±0.5 dB. Frequency
counter accuracy 0.1 ppm 〈±80 Hz).
RF generator; frequency res. 10 Hz amplitude res. 0.1 dB frequency stab.
±0.25 ppm.
Spectrum analyzer; dynamic range 70 dB, accuracy ±1 dB (For power level
measurement accuracy ±0.5 dB).