User Guide
Nokia Customer Care RF Description and Troubleshooting
2115i/2116/2116i (RH-66)
Issue 1 03/2005 ©2005 Nokia Corporation Company Confidential Page 27
Receiver Logic Input Voltages
Following are the measure logic levels for the Rx front end (N7160).
Figure 19: Rx logic input voltages
Table 8 includes the logic level values for the Rx front end.
If the logic levels are significantly off (+/- 0.2 V), replace the N7160 and re-measure. If
the voltages are still out of specifications, refer to the Baseband Description and
Troubleshooting chapter.
Table 8: Rx Front-end Logic Levels
Mode
Logic Input Voltages
1
IF_SEL
2
BAND
3
GAIN_CTL
Cell CDMA high gain 0 V 0.1 V 2.75 V
Cell CDMA low gain 0 V 0.1 V 0 V
PCS CDMA high gain 0 V 2.68 V 2.75 V
PCS CDMA low gain 0 V 2.68 V 0 V
AMPS high gain 2.76 V 0.1 V 2.76 V
AMPS low gain 2.76 V 0.1 V 0 V
2
1
3