User Guide
1$0 &RPSDQ\FRQILGHQWLDO
6\VWHP0RGXOH') &&67HFKQLFDO'RFXPHQWDWLRQ
3DJH È1RNLD&RUSRUDWLRQ ,VVXH
EDWWHU\EXWWKHVLWXDWLRQZRXOGEHWKHVDPHZLWKIXOOEDWWHU\
:KHQWKHSKRQHLVSRZHUHGXSZLWKDQHPSW\EDWWHU\SDFNXVLQJWKHVWDQGDUGFKDUJHU
WKHFKDUJHUPD\QRWVXSSO\HQRXJKFXUUHQWIRUVWDQGDUGSRZHUXSSURFHGXUHDQGWKH
SRZHUXSPXVWEHGHOD\HG
3RZHU8S:LWK7KH3RZHU6ZLWFK3:521;
:KHQWKHSRZHURQVZLWFKLVSUHVVHGWKH3:521;VLJQDOZLOOJRORZ&&217ZLOOVZLWFK
RQWKH&&217GLJLWDOVHFWLRQDQG9&;2DVZDVWKHFDVHZLWKWKHFKDUJHUGULYHQSRZHU
XS,I3:521;LVORZZKHQWKHPVGHOD\H[SLUHV385;LVUHOHDVHGDQG6/((3;FRQWURO
JRHVWR0$',I3:521;LVQRWORZZKHQPVH[SLUHV385;ZLOOQRWEHUHOHDVHGDQG
&&217ZLOOJRWRSRZHURIIGLJLWDOVHFWLRQZLOOVHQGSRZHURIIVLJQDOWRDQDORJSDUWV
Vbat
VBB (2.8V)
CCPURX
PURX
Vchar
12 3
1: Battery voltage over 3.0==>Digital voltages to CCONT (VBB)
2: CCONT digital reset released. VCXO turned on
3: 62ms delay before PURX released
VR1
SLEEPX
VR6
Vref
VBB (2.8
V)
CCPURX
PURX
Vchar
12 3
1:Power switch pressed ==> Digital voltages on in CCONT (VBB)
2: CCONT digital reset released. VCXO turned on
3: 62 ms delay to see if power switch is still pressed.
VR1,VR6
SLEEPX
PWRONX