Figure 44 Measurement points at the RX SAW Filters – Z7600/Z7602
Figure 45 RX I/Q signals
RM-394/RH-118 transmitter
General instructions for GSM 900 TX troubleshooting
Steps
1. Apply a RF-cable to the RF-connector to allow the transmitted signal act as normal. RF-cable should be
connected to an attenuator at least 10dB before connected to the measurement equipment, otherwise
the PA may be damaged.
2. Start
Phoenix
and establish a connection to the phone with the data cable e.g. FBUS.
3. Select File and Scan product.
4. Wait a while for the PC to read the information from the phone.
5. Select Testing and RF Controls.
6. Set the parameters as follows:
i Band: GSM 900
RM-394; RM-395; RH-118
RF Troubleshooting Instructions