User Guide

Table Of Contents
Signal
name
From To Para-meter Input characteristics Function
Min Typ Max Unit
TXP2 UPP RF-IC 1 1.38 1.88 V Depends of
the RF design
(GenIO6
)
0 0 0.4 V
Load
Resistance
10 kW
Load
Capacitanc
e
20 pF
Timing
Accuracy
¼ symbo
l
RFBusEn1
X
UPP RF-IC 1 1.38 1.88 V RFIC Chip SelX
0 0 0.4 V
Internal PU
Current
50 uA
Load
resistance
10 kW
Load
capacitanc
e
20 pF
RFBusDa UPP /
RF-IC
RF-
IC/
UPP
1 1.38 1.88 V Bi-directional
RF Control
serial bus
data,
0 0 0.4 V
Load
resistance
10 kW
Load
capacitanc
e
20 pF
Data
frequency
13 MHz
RFBusClk UPP RF IC 1 1.38 1.88 V RF Control
serial bus bit
clock
0 0 0.4 V
Load
resistance
10 kW
Load
capacitanc
e
20 pF
Data
frequency
13 MHz
RM-394; RM-395; RH-118
System Module
Issue 1 COMPANY CONFIDENTIAL Page 6 –11
Copyright © 2008 Nokia. All rights reserved.