User Guide
Voltage Voltage (V) Condition
HW reset demands
Min 1. 0V d
Max --
a. The nominal voltage is defined as being 15% higher than the lower extreme voltage. TA will test with this
nominal voltage at an 85% range (0.85x3.9V
a
3.3V).
b. This limit is set to be above SW shutdown limit in TA.
c. During fast charging of an empty battery, this voltage might exceed this value. Voltages between 4.20 and
4.60 might appear for a short while.
d. The minimum battery cell voltage required for the reset circuitry to turn on. This is not confirmed by measures
at pt.
Table 6 Current consumption
Condition Min Typical Max Unit
Call (MoU)
(E)GSM 900
GSM 1800
.
208
188
mA
Idle (MoU) 2.72
Power off 150 250 mA
RH-70
General information Nokia Customer Care
9243364 (Issue 1, Part 1) Company Confidential Page 1–9