User Guide

Figure 37 Measurement points at the RX SAW Filters – Z7600/Z7602
Figure 38 RX I/Q signals
Transmitter
General instructions for GSM 900 TX troubleshooting
Steps
1. Apply a RF-cable to the RF-connector to allow the transmitted signal act as normal. RF-cable should be
connected to an attenuator at least 10dB before connected to the measurement equipment, otherwise the
PA may be damaged.
2. Start Phoenix and establish a connection to the phone with the data cable e.g. FBUS.
3. Select File and Scan product.
4. Wait a while for the PC to read the information from the phone.
5. Select Testing and RF Controls.
6. Set the parameters as follows:
i Band: GSM 900
RH-70
Nokia Customer Care RF troubleshooting
Page 2–14 Company Confidential 9243364 (Issue 1, Part 2)
Copyright ©2005 Nokia. All Rights Reserved.