RH-36 Manual Alignment with Phoenix
In Phoenix select connection Fbus and Product Gemini. If you power up the board before
selecting Fbus, it works without any error messages. Use Jig or other device for RF and
bus connection. Attenuation in the probe alone is 0.5dB for 850 and 1dB for 1900. Use
CMD55 or other suitable device.
Default channels are: 37 for GSM850 and
661 for GSM1900.
The alignments must be performed in the order shown to give reliable results.
The way to save data to the phone and to load data from the phone is made different in
the various tunings. Always look what is shown in the windows regarding these issues
and act accordingly.
To vary a selected parameter you can use + and – key or in some cases directly type the
new value. + and – steps the value for every press. Repeat function seems not to work. In
I/Q you can use the side arrows.
RX calibration
Select Maintenance, Tuning, RX Calibration
Select Band: GSM850
Select Automatic and follow the promts
The result should be like the shown: