Product Description

Table Of Contents
Product Description
26 (98) © Nokia Corporation Draft DN991444
Nokia Proprietary and Confidential Issue 3-0 en Draft
Figure 3. Nokia MetroSite BTS Manager Commissioning Wizard
Manual commissioning
Before the commissioning at the BTS site can be started, the following tasks must
be performed:
The LAPD links must be created at the BSC
The PCM port at the BSC must be set to active
The commissioning procedure performed on site with the Nokia MetroSite BTS
Manager includes the following steps:
Transmission configuration
Checking alarms and EACs
Running the tests
Creating the BTS commissioning report
In the near future, the use of the Site Configuration File (SCF) will considerably
ease the commissioning as most of the parameters can be fed directly from the
file, for example, the Abis time slot allocation can be automated.
The Nokia MetroSite BTS Manager automatically produces a commissioning
report at the end of the commissioning process.